PLACING THE SYSTEM IN SERVICE (Continued)
Shutdown/Time Delay/Release Option (Continued)
8. If a vehicle shutdown device is installed and the shutdown
time delay is being used, complete the following steps: See
Figure 39.
a. Affix the “IN CASE OF FIRE” nameplate, Part No. 79060,
near the operatorʼs line of vision.
b. Using Label No. 79404, cut along the dotted line to remove
the required number square.
c. Peel the protective backing from the number square to
expose the adhesive.
d. Place the number square on the space provided in the third
sentence of Label No. 79060: “THIS VEHICLE WILL
AUTOMATICALLY SHUTDOWN AFTER_____SECONDS
FIGURE 39
000886
9. If a vehicle shutdown device is NOT installed, affix the “WHEN
FIRE ALARM SOUNDS” nameplate, Part No. 71086, near the
operatorʼs line of vision. See Figure 40.
FIGURE 40
000887
INSTALLATION
PAGE 24
REV. 02 2012-MAY-18
CHECKFIRE MP-N Electric
Detection and Actuation System Manual