background image

 

1. INDICATIONS AND GENERAL SAFETY RULES 

 

 To guarantee the best working and safety conditions, please read the following 

paragraphs carefully: 

One of the basic safety factors is respecting the maintenance schedule (see 

maintenance chart). Also, never attempt repair or maintenance without the necessary 

experience and / or tools. 

 

ELECTROCUTION 

- Generating sets supply electrical current during use. 

- Never touch damaged cables or disconnected connections. 

- Never handle a generating set with wet hands on feet. 

- Never expose the equipment to liquid splashes or the elements, or place it on a 

wet floor. 

- Keep the electrical cables, as well as the connections, in good condition. 

- The use of material in poor condition can cause electrocution or damage to the equipment. 

- Provide a differential protection device between the generator set and the appliances if the 

The length of the cable (s) you use is greater than 1 meter. 

- Use flexible and resistant cables with a rubber sheath in accordance with current regulations. 

- The generating set must not be connected to other energy sources, such as the public 

distribution network. In the particular case that a reserve connection to networks is foreseen 

existing electrical appliances, this should only be done by a qualified electrician. 

To do this, you must take into account the differences in the operation of the equipment, 

depending on whether the public distribution network or the generator set is used. 

- Protection against electric shock depends on circuit breakers specially provided in the 

generating set. If the latter should be replaced, it should be done by others having identical 

nominal values and characteristics. 

 

FIRE 

-Never refuel the fuel tank while the generator set is running or with a hot engine. 

- Clean any traces of fuel with a clean cloth. 

- Fuel is extremely flammable and its vapors explosive. Don't smoke, come closer 

a flame or sparks when filling the tank with fuel. 

- Keep away any flammable or explosive products (fuel, oil, rags, etc.) when the 

group is underway. 

- Always place the generating set on a level, flat and horizontal ground in order to 

prevent the fuel from the tank from spilling onto the engine. 

- The storage of chemical / oily products and their handling will be carried out in 

accordance with the legal provisions. 

 

EXHAUST GASES 

- Exhaust gases contain a very toxic component: carbon dioxide. This component 

can cause death if it exists in very high concentrations in the breathing 

environment. 

- For this reason, always use your generator set in a well-ventilated place where 

gases cannot accumulate. 

- In addition, good ventilation is required for the proper operation of your generator set. Without 

this ventilation, the motor would rapidly increase the temperature to values that would cause 

accidents or damage to the surrounding material or property. 

- However, if an operation must be carried out inside a building, plan for the 

proper ventilation so that people or animals present are not visible 

affected. 

 

Summary of Contents for GC500TFE

Page 1: ...Instructions and user manual GC500TFE GC7000TFE Millasur SL R a Eduardo Pondal n 23 Pol Ind Sig eiro 15688 Oroso A Coru a 981 696 465 www millasur com EN...

Page 2: ...enance Take this manual with you when you go to work with the machine Contents are correct at time of printing The rights to make alterations are reserved at any time without affecting our legal respo...

Page 3: ...ONTENT 1 INDICATIONS AND GENERAL SAFETY RULES 2 GENERAL INFORMATION 3 INSTRUCTIONS FOR USE 4 MAINTENANCE 5 STORAGE 6 TROUBLESHOOTING 7 TECHNICAL SPECIFICATIONS 8 WARRANTY 9 ENVIRONMENT 10 CE DECLARATI...

Page 4: ...public distribution network or the generator set is used Protection against electric shock depends on circuit breakers specially provided in the generating set If the latter should be replaced it sho...

Page 5: ...sparks do not start a fire Clear a sufficiently large area where you plan to move your generator set GENERAL SAFETY TIPS Before using the group it is necessary to know how to stop the group immediatel...

Page 6: ...ou have all of your equipment The handling of a group must be done with care having prepared in advance the displacement destined for its use or storage DESCRIPTION This generator set includes a 4 str...

Page 7: ...ded fuel Check the engine fuel level before each start Use only approved fuel Do not start the engine when it contains insufficient fuel Never use dirty fuel oil mixture or fuel The use of unauthorize...

Page 8: ...sheltered from the elements Provide good ventilation in case of use inside a room even if this use is exceptional Install the generating set in a place that does not obstruct the passage of people or...

Page 9: ...the engine does not start after 5 seconds stop the attempt and wait 10 seconds before trying again Once the engine is running turn the ignition key back to the ON position NOTE OIL WARNING SYSTEM Flas...

Page 10: ...l to ensure correct use of the generator set s rated output CAUTION The generator set can operate at its rated output only under constant temperature pressure and humidity Variation in temperature pre...

Page 11: ...that determines the maintenance schedule Therefore if the engine works in extreme conditions it should adopt shorter intervals between operations Use the program provided to establish your own progra...

Page 12: ...ng a used spark plug tighten it only 1 8 to 1 4 turn after inserting it by hand to compress the washer 4 4 CLEANING THE AIR FILTER ELEMENT Remove the air filter cover Remove the cartridge from the cap...

Page 13: ...and charge the battery for 20 minutes If the unit still cannot be started with the electric starter replace the battery as follows Disconnect the positive and negative poles of the battery with cables...

Page 14: ...cylinder head fins cooling pan the flywheel and exhaust grille 5 Clean the generator set 6 Cover the alternator air inlets and outlets with plastic tape 7 Store the generator set in a clean dry place...

Page 15: ...the electrodes E If there is no spark replace the spark plug SYMPTOM Overheating PROBABLE CAUSES 1 Are the ventilation air inlets blocked 2 Probable overheating CORRECTIVE ACTIONS 1 Clean the suction...

Page 16: ...ntilation slots lubrication cleaning storage etc Your purchase invoice should be kept as proof of the purchase date Your tool must be returned to your dealer in an acceptable and clean condition in it...

Page 17: ...rushing or abrasion 7 In 2 stroke cycle engines damage caused by incorrect gasoline oil mixtures inappropriate lubricants inappropriate fuel poor quality or contaminated fuel 8 In gasoline or diesel 4...

Page 18: ...in safety and health of the aforementioned CE directives This declaration validates the product to display the CE symbol In the event that the machine is modified and this modification is not approve...