5
If there are two or more elements that need electrical power and
that have to be connected to the generator set, make sure to
connect them one by one and the one with maximum power first,
continuing with the second element with the highest power.
In the case of power supply in a home or circuit, NEVER connect
the generator to the main electricity supply line and cancel the
connection to the outside line by breaking the circuit at the main
input differential.
WARNING: Damage and / or fire in the generator. When it is necessary to connect
the generator to a power source in a building, make sure you have a qualified
electrician to do the job. Improper connection between the generator and the loads
can cause damage to the generator, including fire and serious damage to the installation.
Familiarize yourself with the parameters on the control panel to ensure correct use of the
generator set's rated output CAUTION The generator set can operate at its rated output only
under constant temperature, pressure, and humidity. Variation in temperature, pressure and
humidity can influence the generator output power.
The temperature range in which the unit can be started is 15ºC -40ºC. Standard conditions
are:
- Environmental temperature: 25ºC.- Atmospheric pressure: 100kPa- Relative humidity: 30% .-
Height above sea level: 1000 m
Pay particular attention to the connection of the positive and negative poles on the generator.
CAUTION The generator's current output must not be used as a power source
to charge the battery.
STOPPING THE ENGINE
IN AN EMERGENCY:
1- To stop the engine in an emergency, turn the switch to the OFF / OFF position
IN NORMAL USE:
1- Turn the power cut-off to the OFF / Off position.
2- Disconnect all the electrical outlets found on the panel. Disconnect the battery charging
cables.
3- Turn the ignition switch to the OFF / OFF position.
4- Turn the fuel cock to the CLOSED position.
RIGHT
INCORRECT
RIGHT