3
Gamma C
- a gamma setting
Store
- saves adjusted values into memory
Calibration of pan/tilt/focus via the control board.
1. Disconnect DMX controller from the fixture and enter the "Calib" menu.
2. Enter the "Cal PTF" menu.
3. Use the [PREV] and [NEXT] to find "Pan" and press [ENTER].
4. Set desired value and save it by pressing [ENTER].
5. Repeat steps 3 and 4 for tilt and focus.
6. After calibrating all effects, find item "Store" and press [ENTER]. to save all adjusted values and reset the
fixture.
Calibration of white colour and gamma curve.
1. Disconnect DMX controller from the fixture and enter the "Calib" menu.
2. Enter the "Manual" menu, open shutter and dimmer and set "Cyan", "Magen" ,"Yellow", "Virt C" items to 0.
3. Enter the "Cal Col" menu. By means of the Red, Green and Blue items adjust the 8000K colour temperature
as exactly as possible (∆u´v´= 0).
4. After calibrating, find item "Store" and press [ENTER]. to save all adjusted colours and reset the fixture
Sw Upd
-
Graphical software update.
The item starts update of the graphical software in the fixture.
Insert the USB flash drive with update file into USB port, select this option and press [ENTER]. Version of the
new software will be displayed, eg, v 003 ?.
If you want to run update, press [ENTER] again.
HW Upd
-
HW processors Software update.
The item starts update of hardware functions like pan, tilt,
focus...etc. and should be performed after graphical
software update
To perform software update of the fixture
. Connect the MiniMe to the mains.
2. Plug the USB flash drive into the fixture.
3. Initialize the USB flash drive (via menu "Init USB") and unplug it.
4. Plug the USB flash drive into computer.
5. Download update file from Anolis website into your computer.
Note: Please make sure the full name of the update file is minime_vxxx.tar.gz
(vxxx=version number) before you upload it into the USB flash drive.
6. Upload update file into folder (update) and unplug it.
7. Plug the USB flash drive back into the MiniMe.
8. Run graphical software update via menu "Sw Upd".
9. Run HW processors software update via menu " HW Upd".
6. Keystones
If an image is output from the Robin MiniMe at an angle, the image may be skewed.