10. Maintenance and cleaning
DANGER !
Disconnect from the mains before starting any
maintenance work
A soft lint-free cloth moistened with any good glass cleaning fluid is recommended, under no circumstances
should alcohol or solvents be used!
Never use alcohol or solvents for cleaning lenses !
Use wet cloth only.
It is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid residues must not build
up on or within the fixture. Otherwise, the fixture‘s light-output will be significantly reduced. Regular cleaning will
not only ensure the maximum light-output, but will also allow the fixture to function reliably throughout its life.
Lenses may require monthly cleaning as smoke-fluid tends to building up residues, reducing the light-output
very quickly. The cooling fan should be cleaned according to the situation (at least annually).
The interior of the base should be cleaned at least annually using a vacuum-cleaner or an air-jet.
More complicated maintenance and service operations are only to be carried out by authorized distributors.
Disassembly of the ArcPar 100:
Important: The correct order of parts at the mounting yoke assembly is: insertion piece+rubber yoke+metal
tilt lock (on both sides of the device). The correct orientation of the insertion piece must be kept.
10.1 Replacing the fuse
Replace the fuse by a fuse of the same type and rating only.
Before replacing the fuse, unplug mains lead!
1) Remove the fuse holder on the rear panel of the base with a fitting screwdriver from the housing (anti-clock
-
wise).
2) Remove the old fuse from the fuse holder.
3) Install the new fuse in the fuse holder (only the same type and rating).
4) Replace the fuseholder in the housing and fix it.