background image

33

10. Maintenance and cleaning

DANGER !

Disconnect from the mains before starting any

maintenance work

A soft lint-free cloth moistened with any good glass cleaning fluid is recommended, under no circumstances 

should alcohol or solvents be used!

Never use alcohol or solvents for cleaning lenses !

Use wet cloth only.

It is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid residues must not build 

up on or within the fixture. Otherwise, the fixture‘s light-output will be significantly reduced. Regular cleaning will 

not only ensure the maximum light-output, but will also allow the fixture to function reliably throughout its life. 

Lenses may require monthly cleaning as smoke-fluid tends to building up residues, reducing the light-output 

very quickly. The cooling fan should be cleaned according to the situation (at least annually).

The interior of the base should be cleaned at least annually using a vacuum-cleaner or an air-jet.

More complicated maintenance and service operations are only to be carried out by authorized distributors.

Disassembly of the ArcPar 100:

Important: The correct order of parts at the mounting yoke assembly is: insertion piece+rubber yoke+metal 

tilt lock (on both sides of the device). The correct orientation of the insertion piece must be kept.

10.1 Replacing the fuse

Replace the fuse by a fuse of the same type and rating only.

Before replacing the fuse, unplug mains lead!

1) Remove the fuse holder on the rear panel of the base with a fitting screwdriver from the housing (anti-clock

-

wise).

2) Remove the old fuse from the fuse holder.

3) Install the new fuse in the fuse holder (only the same type and rating).

4) Replace the fuseholder in the housing and fix it.

Summary of Contents for ArcPar 100

Page 1: ...Version 1 4 US...

Page 2: ...map 15 5 Robin ArcPar 100 DMX chart 17 5 1 Virtual colour wheel colour mixing chart 20 5 2 LED zone order 24 6 Control menu Standard and Easy control mode 25 6 1 Addressing and master slave setting D...

Page 3: ...ng the fuses or any part The power plug has to be accessible after installing the fixture Do not overload wall outlets and extension cords as this canresult in fire or electric shock Do not allow anyt...

Page 4: ...en rigging derigging or servicing the fixtu re Do not block the front objective LEDs with any object when the fixture is under operation The fixture becomes very hot during operation Allow the fixture...

Page 5: ...2 Fixture exterior view 4 DMX OUT 5 DMX IN 6 Fuse holder 7 Mains IN 8 Mains OUT 9 Display and control butto ns 10 Safety wire attachment poin t 1 Mounting holder 2 Tilt locks 3 Lens array...

Page 6: ...about proper installation consult a qualified electrician Core EU Core US Connection Plug Terminal Marking Brown Black Live L Light blue White Neutral N Yellow Green Green Earth This device falls unde...

Page 7: ...t the fixture from mains 2 Insert the screw 1 with the plastic washer 2 into diffuser 3 and secure it by means of the plastic washer 4 2 Insert the diffuser 3 into the ArcPar 100 and secure it by scre...

Page 8: ...from mains 2 Screw the accessory frame adaptor 1 on the ArcPar 100 housing with the four screws M4x8 2 and unlock the spring lock 3 via pushing this spring lock as show red arrows on the picture 3 Ins...

Page 9: ...Secure both accessories by moving the spring lock 3 up as shows the red arrow on the picture Note the barndoors can be rotated to desired position and secured in this position via the securing screw...

Page 10: ...ide areas where persons may walk by or be seated IMPORTANT OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE including calculating working load limits installation material being used and periodic safety...

Page 11: ...11 When installing fixtures side by side avoid illuminating one fixture with another 1 Clamp 2 Trust 3 Safety wire 4 Attachment point 5 Folded mounting yoke...

Page 12: ...puts you need to use adapter cables Building a serial DMX chain Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture Always connect one output with the...

Page 13: ...ected with the fixture NOTE when you disconnecting the DMX wireless module from the fixture press and hold lock 5 during get ting the wireless module out To link the fixture with DMX transmitter The f...

Page 14: ...r programs Every slave runs its program according to the program number of the master E g if the master runs program number 3 all slaves run their programs number 3 Note if the option Play Master is s...

Page 15: ...On Time Total Reset DMX In Powr 0 255 Dim F 0 255 Temp Current Highest High Res Sw Ver IC 1 IC 2 Pers DMX Pres Mode 1 Mode 7 Display Turn On Off T On Off Contrast 0 100 Backlight 0 100 C Cal M On Off...

Page 16: ...1 All Pr Edit Prog 1 Step 1 Powr Prog 2 Prog 3 Step 40 F Tim 0 25 5 S Tim 0 25 5 COPY Prg En 1 40 Special RDM Low RDM Hight Wireless Stat Unlink Adjust DMX Val Powr 0 255 Dim F 0 255 Calib Cal Col Re...

Page 17: ...proportional 2 2 1 1 0 255 Red Cyan 8 bit all zones Red LEDs saturation control 0 100 proportional 3 0 255 Red Cyan fine 16 bit all zones Fine red LEDs saturation control proportional 4 3 2 2 0 255 G...

Page 18: ...e LEDs saturation control proportional 16 21 0 255 White 8 bit zone 2 If RGBW mode is selected White colour saturation control coarse 0 100 If CMY mode is selected No function proportional 17 22 0 255...

Page 19: ...ntrol On channel Special Functions The following effects are controlled by sound Rainbow effect with fade time Rainbow effect Zone effect 1 Zone effect 2 Zone effect 3 Zone effect 4 Zone effect 5 Rand...

Page 20: ...22 0 18 255 0 23 0 21 255 0 24 0 24 255 0 25 0 27 255 0 26 0 30 255 0 27 0 36 255 0 28 0 41 255 0 29 0 46 255 0 30 0 52 255 0 31 0 58 255 0 32 0 64 255 0 33 0 68 255 0 34 0 74 255 0 35 0 80 255 0 36...

Page 21: ...4 0 81 0 255 58 0 82 0 255 52 0 83 0 255 46 0 84 0 255 41 0 82 0 255 36 0 86 0 255 30 0 87 0 255 27 0 88 0 255 24 0 89 0 255 21 0 90 0 255 18 0 91 0 255 15 0 92 0 255 12 0 93 0 255 9 0 94 0 255 6 0 95...

Page 22: ...255 246 0 0 137 255 237 0 0 138 255 228 0 0 139 255 219 0 0 140 255 210 0 0 141 255 201 0 0 142 255 192 0 0 143 255 183 0 0 144 255 174 0 0 145 255 165 0 0 146 255 156 0 0 147 255 147 0 0 148 255 138...

Page 23: ...0 68 0 193 255 0 74 0 194 255 0 80 0 195 255 0 86 0 196 255 0 92 0 197 255 0 98 0 198 255 0 104 0 199 255 0 110 0 200 255 0 119 0 201 255 0 129 0 202 255 0 138 0 203 255 0 147 0 204 255 0 156 0 205 25...

Page 24: ...1 110 0 255 0 232 104 0 255 0 233 98 0 255 0 234 91 0 255 0 235 84 0 255 0 236 77 0 255 0 237 70 0 255 0 238 63 0 255 0 239 56 0 255 0 240 49 0 255 0 241 42 0 255 0 242 35 0 255 0 243 28 0 255 0 244 2...

Page 25: ...xture on the display shows adjusted dimmer intensity and colour before switching the ArcPar 100 off When the fixture is switched off both adjusted color and light intensity are saved into memory to us...

Page 26: ...er to 0 press and hold both NEXT and PREV buttons and the Enter button at the same time DMX In DMX readout The menu is used to read DMX values of each channel received by the fixture Temp Temperature...

Page 27: ...controller which will show you some possibilities of using the ArcPar 100 6 6 Stand alone St Alone The ArcPar 100 offers seven built in programs Prog 4 Prog 9 and All and three user editable programs...

Page 28: ...nk fixture from wireless DMX Adjust Adjustment The menu allows the fine adjustment of effects DMX Val DMX values Use the menu to set DMX values of fixture s channels Calib calibration of white colour...

Page 29: ...Universal Interface if the USB port is used If the connection is OK click on the Start Uploading button to start uploading It will take several minutes to perform software update If the option Increm...

Page 30: ...ion 200W 230V I 0 87A power factor 0 97 Optic Light source 12 Osram Ostar RGBW multichips 3 zones with individual colour control of each Min LED life expectancy 60 000 hours RGBW colour mixing CTO Bea...

Page 31: ...DMX 512 1986 1990 and 512 A Full DMX fidelity and frame integrity Auto sensing of DMX frame rate and frame size 5ms DMX latency Operational frequency range of 2402 2480 MHz Producer LumenRadio Connect...

Page 32: ...ite 1 piece P N 10980217 Diffuser 10 for Parfect 100 white 1 piece P N 10980216 Diffuser 40 for Parfect 100 white 6 pieces P N 10980214 Diffuser 20 for Parfect 100 white 6 pieces P N 10980218 Diffuser...

Page 33: ...output very quickly The cooling fan should be cleaned according to the situation at least annually The interior of the base should be cleaned at least annually using a vacuum cleaner or an air jet Mo...

Page 34: ...l Version of the manual Date of issue Description of changes 1 1 29 05 2014 DMX chart added mode 6 RGBW 1 2 05 01 2015 Easy control mode added 1 3 14 10 2015 DMX chart added mode 7 1 4 06 05 2016 Sile...

Page 35: ...35...

Page 36: ...36...

Page 37: ...37...

Page 38: ...38...

Reviews: