background image

ArcPad Xtreme (Single colour) 

 

15 

6.1 Fixture Address  

 

Use this menu to set the DMX address of the fixture or set the fixture as a Master (Slave). 

dM.Ad.

 --- 

DMX addressing

. Select this submenu to set a DMX start address. 

To set a DMX address. 

1.

 

Use the UP/DOWN buttons to find “ 

A001

“ menu. 

2.

 

Press the ENTER button. 

3.

 

Use the UP/DOWN buttons to select desired start address. 

4.

 

Press the ENTER button to confirm the choice. 

 

 

 

MA.SL. --- Master/slave addressing

. Select this submenu to set the fixture as a master or slave. Option "

d.AbL

deactivates master/slave setting. 
To set a fixture as a master or slave. 

1.

 

Use the UP/DOWN buttons to find “A001“ menu. 

2.

 

Press the ENTER button. 

3.

 

Use the UP/DOWN buttons to select  “ 

MA.SL.

“  item. 

4.

 

Press the ENTER button. 

5.

 

Use the UP/DOWN buttons to select either  master (MASt) or slave (SLA) 

6.

 

Press the ENTER button to confirm the choice. 

 

Note

: After switching on, the ArcPadXtreme will automatically detect whether DMX 512 data is received or not. 

If there is no data received at the DMX input, the display will start to flash “A001” with actually set address. 
 

6.2 Fixture information 

 

Use this menu to read useful information about the fixture status. 
To display desired information.  

  

1.  Use the UP/DOWN buttons to find the “ InFo“ menu. 
2.  Press the ENTER button. 
3.  Use the UP/DOWN buttons to select the required menu item. 
4.  Press the ENTER button to confirm the choice. 

 

Po.ti. 

 ---

 Power On Time.

 Use the menu item to read the number of operation hours for each LEDs operating  

mode. 

totL

 - the function shows the total number of the operation hours since the ArcPad Xtreme has 

been fabricated.  

 

 

rESEt

 - the function shows the number of the operation hours that the ArcPad Xtreme 

 

 

has been powered on since the counter was last reset. In order to reset this 
 counter to 0 you have to press and hold the UP and DOWN buttons and at the same time press  
the ENTER button.  

 

 

 

 

DM.In.

---

DMX values

. Select this function to read DMX values of each channel received by the fixture. 

 

 

 

 

 

 

tEMP

 ---

 Fixture Temperatures.

 Select this menu to read the temperatures of the fixture: 

 

 

Cur.t. 

 --- the current temperature of the fixture inside. 

 

 

Hi.tE.

 - the menu item shows the max. temperatures of the fixture inside since 

 

 

the ArcPad Xtreme has been fabricated.  

 

 

rSEt

 --- the menu item shows the maximum temperatures of the fixture inside since the counter 

 was last reset. In order to reset this counter to 0 you have to press and hold the UP and DOWN 
 buttons and at the same time press the ENTER button.  

Summary of Contents for ArcPad Xtreme

Page 1: ...Version 1 7...

Page 2: ...connection 8 3 6 Master slave connection 8 3 7 Stand alone operation 9 4 ArcPad Xtreme Single colour DMX protocol 10 5 Control menu map 11 6 Fixture menu 13 6 1 Fixture Address 15 6 2 Fixture informat...

Page 3: ...ture from AC power before cleaning removing or installing the fuses or any part Do not overload wall outlets and extension cords as this can result in fire or electric shock Make sure that the power d...

Page 4: ...0 minutes prior to manipulate with it Operate the fixture only after having familiarized with its functions Do not permit operation by persons not qualified for operating the fixture Most damages are...

Page 5: ...4 or each module separately by means of the self locking screws Danger of injury Two workers have to handle with the fixture including adjusting the LED modules to the desired position The LED modules...

Page 6: ...ve for the power supply and next 2 shielded cores are intended for DMX connection The power cores are coloured according to the following table Core Connection Plug Terminal Marking Black Live L Blue...

Page 7: ...e steps for the second LED module of the fixture Never close the barn doors during fixture operation 3 4 Setting and control For setting DMX address selecting DMX mode and for another settings you nee...

Page 8: ...MX output with the input of the next fixture until all fixtures are connected Do not overload the link Max 32 fixtures may be connected on a DMX link Caution Terminate the output of the last fixture w...

Page 9: ...neous program start in the other slave fixtures All fixtures have a definite synchronized starting point when playing back their programs The number of running program is the same in all slaves and de...

Page 10: ...4 159 160 191 192 223 224 255 Strobe both LED modules Shutter closed Shutter open Strobe effect from slow to fast Shutter open Opening pulses in sequences slow fast Closing pulses in sequences fast sl...

Page 11: ...Level 3 Menu Level 4 Menu Level 5 Menu Level 6 A001 dM Ad 001 512 MA SL d AbL MASt SLA InFo Poti totL totL rSEt rSEt DM In rEd1 0 255 F dim 0 255 tEMP Cur t boAr LEdS Hi tE boAr LEdS rSEt boAr LEdS V...

Page 12: ...4 Menu Level 5 Menu Level 6 EcO In Po CoL 1 0 255 F dim 0 255 Stor dFSE MAn M PrE C CoL 1 Co1 1 Co1 3 dimr dim0 dim 7 Man C rEd1 0 255 F dim 0 255 TESt St AL Auto Off tESt PrG 1 PrG 3 PLAY tESt PrG 1...

Page 13: ...ctions ESCAPE button leaves menu without saving changes ENTER button enters menu confirms adjusted values and leaves menu UP and DOWN buttons move between menu items on the same level sets values Robe...

Page 14: ...ArcPad Xtreme Single colour 14 The Remote LED Display window will appear Now you can fullly control the fixture using the UP Down Enter Escape and Reset buttons...

Page 15: ...formation about the fixture status To display desired information 1 Use the UP DOWN buttons to find the InFo menu 2 Press the ENTER button 3 Use the UP DOWN buttons to select the required menu item 4...

Page 16: ...rn the display by 180 tEM U Temperature Unit Use this menu in order to display the fixture temperatures in desired units C or F LoAd Load of LEDs The menu allows to choose 2 operating modes for fixtur...

Page 17: ...ENTER button 3 Use the UP DOWN buttons to select Auto item 4 Press the ENTER button 5 Use the UP DOWN buttons to select desired program 6 Press the ENTER button to confirm the choice PLAY Playing prog...

Page 18: ...array can be calibrated separately Users should not change the setting Hold Hold DMX If the function is on the last received DMX values are held in case that DMX data receiving was interrupted e g di...

Page 19: ...n a DMX link 2 Connect the Robe Universal Interface to the fixture and switch this fixture to the update mode 1 Run the RDM Network and select menu item Remote LED Display 2 Use the UP DOWN buttons to...

Page 20: ...Remote Device Management is a bi directional communications protocol for use in DMX512 control systems it is the new open standard for DMX512 device configuration and status monitoring The RDM protoco...

Page 21: ...ABEL SENSOR_DEFINITION SENSOR_VALUE DISPLAY_LEVEL DEVICE_RESET DMX_PERSONALITY DMX_PERSONALITY_DESCRIPTION STATUS_MESSAGES STATUS_ID_DESCRIPTION DEVICE_HOURS 8 Error and information messages t M Er Te...

Page 22: ...ode L70 One LED channel Full mode Eco mode 95 000 108 000 Two LED channels Full mode Eco mode 90 000 102 000 Three LED channels Full mode Eco mode 84 000 95 000 All LED channels Full mode Eco mode 77...

Page 23: ...ArcPad Xtreme Single colour 23 Temperatures Maximum ambient temperature 40 C Maximum housing temperature 85 C Dimensions mm ArcPad Xtreme...

Page 24: ...o 99012672 1 x User manual 1 x Gasket of cable grommet M20 PF P N 1305 1388 Optional accessories Barn doors in silver colour No 10980081 Top hat in silver colour No 10980087 Half top hat in silver col...

Page 25: ...ft brush or sponge and a mild non abrasive washing detergent Rinse it There are no serviceable parts inside the device Maintenance and service operations are only to be carried out by a qualified pers...

Page 26: ...s and the control unit The Chogori connectors are marked by self adhesive labels LED1 LED2 LED3 LED4 next to the connectors and the following order of cable connections has to be kept to ensure correc...

Page 27: ...must be grounded in accordance with all national and local electrical and construction regulations In case that LED modules and the base are installed separately on the insulant e g wall LED modules...

Page 28: ...ArcPad Xtreme Single colour 28 Dimensions mm Weight LED module with mounting bracket 24 kg Control unit 9 kg Specifications are subject to change without notice July 21 2014...

Page 29: ...ArcPad Xtreme Single colour 29...

Reviews: