AWG08-001 Audio Warning Generator
Installation and Operation Manual
January 21, 2019 Rev: 1.01
Page 1-3
ENG-FORM: 800-0100.DOTX
CONFIDENTIAL AND PROPRIETARY TO ANODYNE ELECTRONICS MANUFACTURING CORP.
1.3.2
Warning Audio Storage [Non-TSO]
The AWG08 is able to store up to eight stored digitally sampled warning tones or messages. The warnings
are configurable by use of a PC Application. The warning’s digitally sampled data is stored on internal non-
volatile memory.
The AWG08 may be factory configured to store four warnings/messages with extended message lengths.
The AWG08 utilizes memory modules with a playback endurance of >100k cycles and message retention
of >10 years.
The AWG08-001 user configurable audio is preloaded from factory with the following warnings in their
respective trigger locations as described below:
Trigger
Position
File Name
Pre-loaded
Message
Length (s)
Max
Message
Length (s)
Trigger 1
Voice Engine Fire Female.wav
~1.0
85 /170
Trigger 2
Voice Rotor High Male.wav
~1.0
85 /170
Trigger 3
Voice Rotor Low Male.wav
~1.0
85 /170
Trigger 4
VA Pull Up Female.wav
~3.2
85 /170
Trigger 5*
Alert OVERSPD.wav
~0.9
85 / -
Trigger 6*
Voice Altitude Female.wav
~0.8
85 / -
Trigger 7*
Voice Decision Height Male.wav
~1.0
85 / -
Trigger 8*
Alert GEAR.wav
~1.8
85 / -
*
Note:
These Triggers can be disabled with a factory only configuration setting. Disabled
triggers double the available maximum message length for Triggers 1
– 4. Triggers cannot be