1.5.5
User Configurable Settings [Non-TSO]
AWG08 user configurable settings and warning changes require a PC with the latest version AWG-APS
software installed. Contact AEM customer sales for the latest version of AWG-APS.
1.5.6
Embedded Programmer [Non-TSO]
The AWG08 functions without the use of a programmable microprocessor. The embedded programmer is
not powered during flight and is intended to configure options within the AWG08 as a maintenance
activity while the connected aircraft is powered down. The AWG08 embedded programmer is powered by
a separate internal USB power supply. When the USB power supply is energized by a connected
computer while the aircraft power is on, the AWG08-001 disables its internally stored audio playback
circuitry and enables the emergency audio paths.
The embedded microprocessor (powered only during maintenance) communicates to a PC with a custom
PC application.
The embedded programmer configures the onboard non-volatile warning storage and non-volatile digital
switch settings during maintenance only. The performance of the non-volatile warning storage and non-
volatile digital switch settings is unaffected by environmental conditions. The ability to change these
configurations was tested in normal environmental conditions at room temperature only.
1.6
Additional Requirements
1.6.1
Bonding
Bonding Resistance:
≤2.5mΩ
End of Section 1.0