AWG08-001
Environmental Qualification Form
Rev: 1.00
Nov 2, 2018
Page 3 of 5
ENG-FORM: 521-0100.DOTX
CONFIDENTIAL AND PROPRIETARY TO ANODYNE ELECTRONICS MANUFACTURING CORP.
Conditions
Section
Description of Conducted Tests
Audio Frequency Susceptibility
Ripple Voltage
18.0
Equipment tested to Category Z
0.6 Vpp from 10 to 200 Hz,
to 1.6 Vpp from 0.2 to 1 kHz,
to 4.0 Vpp from 1 to 15 kHz,
to 0.6 Vpp at 15 kHz,
to 0.004 Vpp at 148.5936 kHz
Induced Signal Susceptibility
Magnetic Fields into Equipment
Electric Fields into Equipment
Magnetic Fields into Cables
Electric Fields into Cables
Spikes Induced into Cables
19.0
19.3.1
19.3.2
19.3.3
19.3.4
19.3.5
Equipment tested to Category ANE
20 Arms @ 350 and 650 Hz
170 Vrms @ 400 Hz
18 A
•
m @ 350 to 650 Hz,
360 V
•
m from 350 to 650 Hz
Positive and negative spikes as per DO-160G
Radio Frequency Susceptibility
Conducted RF Susceptibility
Radiated RF Susceptibility
20.0
20.4
20.5
Equipment tested to Category TT
(Reference Remarks: Item 3.)
0.15 mA @ 10 kHz,
to 0.36 mA @ 24 kHz,
to 7.5 mA @ 24 kHz,
to 7.5 mA @ 400 MHz
SW/CW: 5 V/m from 100 to 400 MHz
Radio Frequency Emission
Conducted RF Emission
Radiated RF Emission
21.0
21.4
21.5
Equipment tested to Category L
Power lines: 150 kHz to 152 MHz
Interconnecting Cables: 150 kHz to 152 MHz
100 MHz to 6 GHz
Lightening Induced Transient
Susceptibility
Pin Injection
Cable Bundle
22.0
22.5.1
22.5.2
Equipment tested to Category XXZ2XX
N/A
Single Stroke Requirements: Waveforms 1/2, 3
and 4
Multiple Stroke Requirements: N/A
Multiple Burst Requirements: N/A
Lightning Direct Effects test
23.0
Category X, no test performed.