Section 2.0 Installation 

2.1 

Introduction  

Information in this section consists of: unpacking and inspection procedures, installation procedures, post-
installation checks, and installation drawings.  

2.2 

Unpacking and Inspection   

Unpack the equipment carefully.  Inspect the unit visually for damage due to shipping and report all such 
claims immediately to the carrier involved.  Note that each unit should have the following: 

 
- AWG08-001 
- Acceptance Test Report 
- Certificate of Conformity or Release certification 
- USB Cable 
 

Verify that all items are present before proceeding and report any shortage immediately to your supplier. 
 

2.2.1 

Warranty 

All Anodyne Electronics Manufacturing Corp. (AEM) products are warranted for 3 years. See the website 
www.aem-corp.com/warranty for complete details. 

2.3 

Installation Procedures 

2.3.1 

Warnings 

 

WARNING:

 

High volume settings can cause hearing damage. Proper personal 

protective equipment is required to prevent hearing damage.  

2.3.2 

Cautions 

CAUTION: 

The AWG08 inputs and outputs are adjusted from factory to achieve 100mW 

rated output into a 600 Ohm load for Audio Output 1 and 2. 

The AWG08 audio outputs are not intended to drive load impedances less than 

600 Ohms. Audio output or warning level adjustments to achieve clear and 

comfortable sound pressure levels may be required. 

 

Warning audio output levels are dependent on the signal level set in the loaded 

warning file. All warning file signal levels should be verified to be similar. 

 

 

Summary of Contents for AWG08-001

Page 1: ...AWG08 IOAWG08 REV 1 01 January 21 2019 Anodyne Electronics Manufacturing Corp 15 1925 Kirschner Road Kelowna BC Canada V1Y 4N7 Telephone 1 250 763 1088 Toll Free 1 888 763 1088 Website www aem corp co...

Page 2: ...NUFACTURING CORP COPYRIGHT STATEMENT 2019 Anodyne Electronics Manufacturing Corp AEM All Rights Reserved This publication is the property of AEM and is protected by Canadian copyright laws No part of...

Page 3: ...d by the revision shown on the title page The status of each section is controlled by revision shown in the footer of each page All revisions affecting sections of this manual have been incorporated A...

Page 4: ...TSO 1 7 1 3 12 Emergency Mode 1 8 1 3 13 Maintenance Mode Non TSO 1 8 1 3 14 Audio Options and Configuration Non TSO 1 8 1 3 15 Warning Active Output Non TSO 1 8 1 4 Specifications 1 9 1 4 1 Electrica...

Page 5: ...2 6 2 7 Installation Drawings 2 7 3 0 Operation 3 1 Introduction 3 1 3 2 General 3 1 3 3 System Interfaces 3 1 3 3 1 Inputs 3 1 3 3 2 Outputs 3 2 3 4 System Operations 3 2 3 4 1 Audio Summing 3 2 3 4...

Page 6: ...rm of a tone or voice or combination thereof The AWG08 provides two un switched adjustable direct auxiliary audio inputs to be summed with the warning audio Pre summed input level is adjustable via ex...

Page 7: ...es This section contains descriptions of the AWG08 001 design features and default factory settings 1 3 1 TSO and Non TSO Functions The AWG08 contains qualified TSO and qualified Non TSO functions The...

Page 8: ...cles and message retention of 10 years The AWG08 001 user configurable audio is preloaded from factory with the following warnings in their respective trigger locations as described below Trigger Posi...

Page 9: ...warning playback will be the higher priority warning Warning trigger 1 has the highest priority and warning trigger 8 has the lowest priority Warnings are configurable by the user to playback once Si...

Page 10: ...pre loaded from factory with the following settings Trigger Cancel Mode Trigger 1 Enabled Trigger 2 Enabled Trigger 3 Enabled Trigger 4 Enabled Trigger 5 Enabled Trigger 6 Disabled Trigger 7 Disabled...

Page 11: ...ed playback The AWG08 001 user configurable input pin state is pre loaded from factory with the following Input Pin State Warning Trigger Disable Active Low Note The state is user configurable between...

Page 12: ...n is released the AWG08 will playback all active or previously active warnings in priority order The external warning active feature is capable of muting the audio inputs to the AWG08 if the Mute Inpu...

Page 13: ...WG08 maintenance mode allows the user configuration settings and warning audio files to be modified by a connected PC The AWG08 does not require aircraft power to modify the user configuration setting...

Page 14: ...Vdc 0 3 A maximum 5 0 Vdc USB Connection Protection Fuse 0 5A Slow Blow Reverse Polarity Power supply inhibited upon 28 Vdc power applied to GND 1 4 1 2 Input Signals Warning Trigger Inputs Non TSO Qu...

Page 15: ...Input Active High 14 5 Vdc 5mA sink Input Active Low 1 0 Vdc 5mA source Input bias 5 k Internal pullup to 5 Vdc Input Protection Diode protected to 45 Vdc maximum Direct Audio Input Quantity 2 Circuit...

Page 16: ...y 1 Circuit Type Active Low Input Active 1 0 Vdc Input Current 5 mA source Input Protection Diode protected to 45 Vdc maximum Emergency Input Quantity 1 Circuit Type Active Low Input Active 1 0 Vdc In...

Page 17: ...vel 60 dB from Rated Power Adjustment Range Output 17 dB Tone Audio 18 dB Output Protection Diode protected to 25 Vpk maximum AC coupled DC blocking Note Internally generated 1 kHz sign wave measured...

Page 18: ...lled in a Master Slave configuration 1 4 1 4 Bidirectional Signals Programming Port Non TSO The AWG08 provides one externally accessible USB port for programming user configurable settings and loading...

Page 19: ...1 5 1 Installation Procedures and Limitations This article meets the minimum performance and quality control standards required by a technical standard order TSO Installation of this article requires...

Page 20: ...s powered down The AWG08 embedded programmer is powered by a separate internal USB power supply When the USB power supply is energized by a connected computer while the aircraft power is on the AWG08...

Page 21: ...s are present before proceeding and report any shortage immediately to your supplier 2 2 1 Warranty All Anodyne Electronics Manufacturing Corp AEM products are warranted for 3 years See the website ww...

Page 22: ...interconnect drawing in Section 2 7 as required Refer to the interconnect drawing in Section 2 7 for shield termination details Aircraft harnessing shall permit the unit to be removed for easy access...

Page 23: ...Settings Non TSO User configurable settings including warning audio summed audio pathway configuration and input settings may be adjusted before installation using the PC programming software The AWG0...

Page 24: ...R AUD IN and warning TONE level These outputs can be adjusted using the AUD OUT level adjustment to better suit specific audio system installations 2 4 4 Level Adjustments Field Adjustable During inst...

Page 25: ...perational routing requirements Connected unit specifications and emergency mode system routing requirements should be assessed before changes are made to the EMERG MODE SUMMING switch configuration T...

Page 26: ...2 Direct Audio Input 1 Direct Audio Input 2 Connected To Audio Output 1 and Audio Output 2 Direct Audio Input 1 Direct Audio Input 2 Connected To None Note Both audio inputs can be disable The AWG08 w...

Page 27: ...hat the document is listed elsewhere in the manual Refer to the applicable AEM Part No to locate the referenced document DOCUMENT REV DESCRIPTION TYPE SER NO AWG08 001 403 0 1 00 Cabin PA Amplifier In...

Page 28: ...0 0 0 1 1 2 3333333333333 333333333333333 3333 333 4 5 4 6 4 5 4 5 17 APR 19 18 Apr 19 18...

Page 29: ...0 1111111111111 111111111111111 1111 111 2 3 2 4 2 3 2 3 5 APR 18 18 Apr 19 18...

Page 30: ...0 1 1 1 APR 18 18 Apr 19 18...

Page 31: ...perature Ground Survival High Temp Short Time Operating High Temp Operating High Temp In flight Loss of Cooling Altitude Decompression Overpressure 4 0 4 5 1 4 5 1 4 5 2 4 5 3 4 5 3 4 5 4 4 5 5 4 6 1...

Page 32: ...Equipment tested to Category Z Deflection of 1 0 D 0 3 m Power input Voltage Average Value DC Momentary Power Interruptions DC Normal Surge Voltage DC Engine Starting Under Voltage DC Voltage Steady...

Page 33: ...50 and 650 Hz 170 Vrms 400 Hz 18 A m 350 to 650 Hz 360 V m from 350 to 650 Hz Positive and negative spikes as per DO 160G Radio Frequency Susceptibility Conducted RF Susceptibility Radiated RF Suscept...

Page 34: ...RONICS MANUFACTURING CORP Conditions Section Description of Conducted Tests Icing 24 0 Category X no test performed Electrostatic Discharge 25 0 Equipment tested to Category A 15 000 Vp 10 positive an...

Page 35: ...s 20 21 and 22 were tested at CKC Laboratories in Bothell WA 3 In Section 20 the equipment was tested with conducted RF Susceptibility levels and frequencies to satisfy the requirements of both DO 160...

Page 36: ...A DO NOT SCALE DRAWING N A SHEET 1 OF 1 DMF LAC 27 Mar 18 8 7 6 5 5 6 7 8 6 5 7 5 7 8 6 8 D C B A C A ______ 0 0625 15 1925 KIRSCHNER RD KELOWNA BC V1Y 4N7 B 0 100 WITHOUT THE WRITTEN PERMISSION OF A...

Page 37: ...SO input interfaces of the AWG08 a Eight independent priority warning trigger WARN TRIG inputs are user configurable for trigger type warning type and cancel mode The eight inputs correspond to the ei...

Page 38: ...ully configurable cross point switch between the audio inputs and outputs See section 2 4 6 3 4 2 Audio Summing Non TSO All AWG08 audio outputs receive warning audio except in emergency mode Warning a...

Page 39: ...ation Manual January 21 2019 Rev 1 01 Page 3 3 ENG FORM 806 0100 DOTX CONFIDENTIAL AND PROPRIETARY TO ANODYNE ELECTRONICS MANUFACTURING CORP 3 4 6 Warning Playback Non TSO The flowchart below describe...

Page 40: ...with an external switch connected to the emergency EMERG input or when the power supply drops below an internal threshold Emergency mode is also activated if the user attempts to make setting changes...

Page 41: ...ator Installation and Operation Manual January 21 2019 Rev 1 01 Page 3 5 ENG FORM 806 0100 DOTX CONFIDENTIAL AND PROPRIETARY TO ANODYNE ELECTRONICS MANUFACTURING CORP 3 4 12 Block Diagram Figure 2 Blo...

Reviews: