1.4
Specifications
1.4.1
Electrical Specifications
1.4.1.1
Input Operating Voltage
Normal Operating Conditions:
Nominal:
+28.0 Vdc
Maximum:
+30.3 Vdc
Minimum:
+22.0 Vdc
Emergency:
+18.0 Vdc
Abnormal Operating Conditions:
Nominal:
+28.0 Vdc
Maximum:
+32.2 Vdc
Minimum:
+20.5 Vdc
Input Current:
0.3 A maximum @ 28.0 Vdc
0.3 A maximum @ 5.0 Vdc (USB Connection)
Protection:
Fuse:
0.5A Slow Blow
Reverse Polarity:
Power supply inhibited upon +28 Vdc power applied to
GND
1.4.1.2
Input Signals
Warning Trigger Inputs [Non-TSO]
Quantity:
8
Circuit Type:
Configurable Active High or Active Low
Input Active High:
+14.5 Vdc,
<5mA sink
Input Active Low:
+1.0 Vdc,
<5mA source
Input bias:
5 k
Internal pullup to +5 Vdc
Input Protection:
Diode protected to +45 Vdc maximum
Warning Audio Cancellation Input [Non-TSO]
Quantity:
1
Circuit Type:
Configurable Active High or Active Low
Input Active High:
+14.5 Vdc,
<5mA sink
Input Active Low:
+1.0 Vdc,
<5mA source
Input bias:
5 k
Internal pullup to +5 Vdc
Input Protection:
Diode protected to +45 Vdc maximum