CONNECTING THE FLOOD SENSOR
(OPTION)
4.1 - Flood sensor input
ANEP BOX-C possesses a function which allows the detections of water in the pit.
An optional kit consisting of a sensor and bracket may be connected to the corresponding input.
Two types of flood sensor can be connected:
- A flood sensor having a free dry contact potential to connect to the input :
- A flood sensor with a powered output (230V max) to be connected to the input:
ANEP BOX-C automatically detects whether the water sensor
is NO or NC, it is therefore necessary to connect the sensor
BEFORE the telephone line.
4.2 - Flood sensor installation
The sensor may be NO or NC.
The sensor ( option) must be installed
in the following way in the pit :
- The floaters at lower extremity above water level.
- The connection and programming
must be done in « ... » conditions,
i.e. no water , condition « normal ».
Water will be detected when floater rises (see diagram).
The start and the end of the event
are transmitted to the call center (memory 104).
4.3 - Detection tiemout
The time before the information is taken
into account for the start and end of the event
can be programmed between 1 to 99 minutes.
In programming mode :
Enter the sequence « # » et « 3 » « 0 » « 2 » followed by the time in minutes
(from 0 to 99 minutes)
The unit plays a melody
Enable by pressing # when the timeout is 0, then the event «FLOOD» is disabled