background image

ANEP BOX-C

Version #1

 09/22/2014

14

3

.5.7 - 

Configuration of the dual call mode

The dual call mode allows a call to a caretaker post (voice only), before making a call to 

the call center(data and voice). In addition, if the function « Acknowledgement of a 

trapped passenger call « is enabled, the caretaker will have to acknowledge the call by 

entering the sequence « #1 « on his phone keypad. Without this acknowledgment, 

BOX-C

 

will call back to the call center up to 6 times.

Configuration of the dual call mode :

To configure the dual call mode, enter in programming mode and dial the sequence #206#

The « telephone « memories should be programmed as follows :

memory 101 : phone number of the caretaker

memory 102 : phone number of the call center

Sequence of an alarm call :

When the emergency elevator telephone button is pushed, 

BOX-C

 calls the number in 

memory 101 (caretaker).

Then it calls the number in memory 102 (call center).

If the number called by memory 101 (caretaker) or 102 (call center) is (are) busy, 

the corresponding numbers are called back up to 6 times.

Disabling

 dual call mode :

To disable the dual call mode, enter in programming mode and dial the sequence #207# 

3.6 - Selection of communication protocol

3.6.1 - 

ANEP Protocol 

Default protocol, or set by the following key sequence :

After entering the access code programming, press 

# 200

 then 0, then 

#

.

3.6.2 - 

P100 Protocol

P100 protocol is set by the following key sequence : 

After entering the access programming, press 

# 200 

then 1, then 

#

.

3.7 - Adjusting the level of emissions of DTMF codes

Ability to adjust the transmission power DTMF codes to avoid echo phenomena when the 

BOX-C

 is connected to a GSM gateway.

By default power is set to -8 dBm.

After entering the access code programming

 

Press 

# 409

 then a value of N 0-12 then 

#

Powser (dBm).

Summary of Contents for BOX-C

Page 1: ...ANEP BOX C www anepstore com PIT EMERGENCY TELEPHONE SYSTEM FOR LIFT...

Page 2: ...ttribution 3 4 1 Transfer method 3 4 2 Programming table for a single call 3 5 Enabling and adjustment of parameters 3 5 1 Conversation timeout 3 5 2 Listen to call identification 3 5 3 Cyclic test pe...

Page 3: ...hang up voice mode CALL TO ANEP S VOICE SERVER SVA PAGE17 6 1 Enable call to SVA 6 2 Making the call to SVA 6 3 Tests made 6 3 1 Audio reception test 6 3 2 ANEP BOX C serial number verification 6 3 3...

Page 4: ...m the pit flooding detector 1 dual fonction key passenger trapped acknowledge and test call to ANEP voice server 1 key for technician alarm Up to 6 telephone numbers may be stored Automatic calling of...

Page 5: ...ANEP BOX C Version 1 09 22 2014 5 1 3 Connecting ANEP BOX C module phone line Dry contact flood sensor Powered flood sensor...

Page 6: ...performance of telephone line equipement depends largely upon the characteristics of the telephone line Particular care must be taken when cabling the phone line to avoid damaging the standard line ch...

Page 7: ...ode 1 2 3 This code may be modified by the technician 1 to 7 digits See page 14 3 1 Enter programming mode Enter followed by the access code to enter programming mode Example using the factory default...

Page 8: ...the acces code to enter programming mode enter the following sequences 303 then 1 if module 1 lift 1 or 303 then 2 if module 2 lift 2 or 303 then 3 if module 3 lift 3 or 303 then 4 if module 4 lift 4...

Page 9: ...mming mode Factory default 123 001 Erasing of configuration and telephone numbers 101 Telephone number 1st Call center phone number 102 Telephone number 2nd Call center phone number 103 Telephone numb...

Page 10: ...number 102 Secondary emergency call number 103 Third emergency call number 3 3 1 Programmaming memories 101 102 103 In programming mode example for the principle call number Enter the sequence 1 0 1 E...

Page 11: ...sfer its ID information and establish a two way voice communication either In a single calls or two seperate call The recommanded method with respect to European specifications is to make a single cal...

Page 12: ...site record must first be established in the software ANEPCENTER refer to the manual ANEPCENTER During programmation mode exit BOX C performs a periodic call immediately NOTE During cyclic call the ce...

Page 13: ...at the factory 3 5 6 Gain Setting in intercom machinery and firefighter modes Ability to independently adjust the Speaker and microphone gains used for Intercom machinery and firefighter module modes...

Page 14: ...elephone button is pushed BOX C calls the number in memory 101 caretaker Then it calls the number in memory 102 call center If the number called by memory 101 caretaker or 102 call center is are busy...

Page 15: ...NC The sensor option must be installed in the following way in the pit The floaters at lower extremity above water level The connection and programming must be done in conditions i e no water conditio...

Page 16: ...e unit is still on line 5 2 Automatically Hang Up Voice mode The unit automatically Hang Up if an engaged signal is detected or if the call timeout is reached ANEP BOX C plays a melody 10 seconds befo...

Page 17: ...Special case make a call to SVA from from behind a PABX Pressing the 0 key at the end of the sequence means that the prefixe 0 will be dialled before the SVA number Direct line 1 2 3 Factory code SVA...

Page 18: ...annouced by the SVA 6 3 3 Installation telephone number check The telephone number of the caller is annonced by SVA 6 3 4 Audio test A vocal message can be recorded and play back immediately by the SV...

Page 19: ...mber for periodic calls 106 Telephone number for internet server 2 Communication 200 Selection of communication protocol 201 Voice call timeout 1 to 99 minutes 202 Call acknowledge by operator functio...

Page 20: ...ANEP BOX C Version 1 09 22 2014 20 NOTE...

Page 21: ...ANEP BOX C Version 1 09 22 2014 21 NOTE...

Page 22: ...ANEP BOX C Version 1 09 22 2014 22 NOTE...

Page 23: ...orte quel moment sans pr avis GARANTIE Ce produit est garanti 1 an compter de la date de facturation du produit l exception des batteries et des piles qui sont garanties 6 mois Toutefois cette garanti...

Page 24: ...4 bis rue de Paris 94470 Boissy Saint L ger FRANCE Tel 33 1 45 98 34 44 Fax 33 1 45 69 75 45 www anepstore com...

Reviews: