AIRSLIM [L]
17
5.6
Safety Cable Installation
The motor comes with an already fixed safety cable that must be fixed to prevent a motor crash once installed.
Place the safety wire on a fixed roof element.
•
If the fan is installed in a concrete ceiling, drill the ceiling and insert a ring that supports the weight of the
fan at 2 to c fro the fan’s ceiling fra e.
•
If the fan is installed in a steel or concrete beam, put the steel safety cable around the beam forming a
closed loop.
•
The safety cable must be fixed with the two cable clamps. The ring clamps are included in the motor box.
Part list:
1. CAT 6 Shielded Data Cable
2. Power cable
3. Safety cable
4. Clamp for safety cable (4x)
Cables 1 2 will come out of the
square hole on side of the Drop
Tube as illustrated
Cable 3 is attached to the motor and
is feed upward
SAFETY!
Ensure that the safety cable is correctly installed to prevent the fan from falling.
Failure to do so may
result in serious personal injury or death and equipment damage.
Leave wire rope loose until