16
O.O.B - Out-of-Beam Display (ON / OF):
When ON a sequence of
arrows is displayed that indicates when the receiver has moved
beyond the vertical laser reception range. The sequence will indicate
which direction to move to get back in the laser beam. The display
remains on for approximately 25 seconds. Default setting is OF.
GRD.A. - Grade Alarm (ON / OF):
Special application function that
when turned ON, disables the audible signal when on-grade. When
moved out of the on-grade deadband, the beeper activates as
normal. Default is OFF (OF).
A.S.O. - Automatic Shut Off (OF / 0.5 / 8):
Selects automatic
shutoff time from last laser strike.
OF:
Automatic shutoff turned Off.
0.5:
30 minute shutoff. Default setting.
8:
8 hour shutoff.
TX.O.L. - Transmitter Out-of-Level (OF / 2.3 / 2.7 / 3.3 / 5.0 / 6.7):
Special Application used with transmitters which communicate to the
receiver that the laser is out of level. The lasers change their rotating
speed when they are out of level. When enabled, the receiver
senses this change and alerts the user. Grade display information is
disabled when activated. Default is OFF (OF).
Conversion table
RPS
RPM
Laser Rotation:
6.7
400
5.0
300
3.3
200
2.7
160
2.3
140