SENS - Sensitivity (LO / MD / HI):
Selects reception sensitivity to
laser and other light sources.
LO
(Low) is used if outside sources are disturbing elevation
readings.
MD
(Medium) is used for most applications and is default setting.
HI
(High) can be used when working with a weak laser beam or if
the beam needs to be picked at very long distances.
NOTE:
Refer
to the laser's specifications for accuracy and distance information.
AVG - Numeric and Arrow Averaging (LO / MD / HI):
Averages
laser beam strikes to improve arrow display performance at long
distances. Averaging is also affected by laser RPM and accuracy
setting.
LO
(Low) uses minimum averaging to display laser strikes.
MD
(Medium) is default setting and used for most applications.
HI
(High) can be used in windy conditions, when the laser beam
may be unstable, or when working at long distances.
NOTE:
Refer to the laser's specifications for accuracy and distance infor-
mation.
D.R.O. - Digital Read Out (OF / DB / HI):
Turns the numeric display
ON (DB) or OFF (OF) or selects high resolution display mode (HI).
Default setting is ON (DB).
UNIT - Units of Measure:
Centimeters (CM), millimeters (MM),
inches (IN) or feet (FT). Default is MM.
ARRW - Arrow Display (DB / PR):
Adjusts how the off-grade arrow
and bars are displayed. Default is DB.
DB
(Deadband): each bar represents the deadband or accuracy
setting.
NOTE:
For larger deadbands, not all bars may be
displayed.
PR
(Proportional): Each bar represents the available vertical
reception range divided by the number of segments.