Operating instructions
33
EN
Controls
Operation mode DHW (M)
For switching on the DHW operation
(indication in display below DHW
symbol).
Operation mode heating zone(s) (I)
For setting 4 different heating
modes:
•
Auto (clock): automatic opera
-
tion by time program;
•
Comfort (sun): 24/7 heating in
comfort mode;
•
Reduction (moon): 24/7 heating
in reduced mode;
•
Standby: heating off, frost pro
-
tection activated.
Display (L)
Info mode (G)
Display possibility of following info
without influence on boiler control:
temperatures, operation mode
Heating / DHW, error code.
Room temperature control (C)
•
for changing room comfort tem
-
perature
•
for changing settings when pro-
gramming.
Legend:
A
B
C
D
E
F
G
H
I
L
M
On/off switch
Return (ESC)
Room temperature control
Confirmation (OK)
Manual mode
Chimney sweeper mode
Info mode
Reset button
Operation mode heating zone(s)
Display
Operation mode DHW
Confirmation (OK) (D)
Return (ESC) (B)
These buttons are used for program-
ming in combination with the wheel.
By pressing the ESC button it’s pos
-
sible to go back one level, changed
values are not taken over by the
controller.
By pressing the OK button it’s pos
-
sible to arrive in the next level or
confirm changed values.
Manual mode (E)
This button is used for switching the
boiler into manual mode. In manual
mode all pumps will run and the
mixing valves are no longer con
-
trolled, the burner setpoint is 60°C
(indicated by spanner symbol).
On/off switch (A)
•
Position 0: boiler and connected
electrical components are no pow
-
ered. Frost protection is not se
-
cured.
•
Position I: the boiler and connect
-
ed electrical components are pow
-
ered and stanby for operation.
Deaeration mode (E)
By pressing the manual mode but
-
ton longer than 3 seconds, the au
-
tomatic hydraulic deaeration is acti
-
vated. During deaeration the system
is put in standby mode
b
.
The pumps are switched on and off
for several times. After deaeration,
the boiler automatically returns to
normal operation.
Chimney sweeper mode (F)
Used for combustion analysis. By
pressing the button once again,
or automatically after 15 minutes,
the chimney sweeper mode will be
deactivated (indicated by spanner
symbol).
Reset button (H)
By shortly pressing the reset button
a burner lockout can be cancelled.
Operating instructions
c
b
0
4
6
12
16 20
24
+
-
ESC
OK
M
A
H
B
C
D E F
I
L
G
Summary of Contents for SUPAflo EVO SF60 EVO
Page 1: ...INSTALLATION AND SERVICE MANUAL SUPAflo EVO Water Heater SF60 EVO...
Page 2: ......
Page 15: ...Installation 15 EN Disassemble the casing 7 8 9...
Page 23: ...Installation 23 EN Wiring diagram Boiler...
Page 46: ...Note 46 Note...
Page 47: ...Note 47 EN Note...