9
Flue Terminal Installation Precautions
Note the following flue terminal installation requirements
• Do not install the flue terminal indoors
• Install the flue terminal with a downward slope
upward
slope
downward
slope
• Install with the proper length protruding through the wall (FF-100A only)
• Avoid storing hazardous
objects near the terminal
Petrol
Gas
Proper installation. The
red line can be seen,but
the red rectangle cannot
be seen from the outside.
Flue Terminal
Flue Terminal
not far
enough
too far
Snow
drift
Tree
• Avoid installing the terminal where obstacles will block it
• Clearance from the flue terminal.
If multiple units are installed,
terminals must be separated by
300mm or more in a plain view
regardless of the vertical clearance.
Flue Terminal
Flue Terminal
300mm or more
300mm or
more
• In the case the discharge direction of the exhaust
is to the side as shown in the diagram below, do
not select the supply/exhaust tube top. Incomplete
combustion caused by short cycling of exhaust
gas may occur as a result.
(except terminal guard.)
8.
Flue Pipe Installation
(Internal Installation Only)
Flue Terminal Installation
• Follow the installation instructions included with the flue terminal and which are reproduced at the end
of this manual. This appliance must be the flue through the wall, not vertically to the roof.
1500mm or more
(terminal above
a terminal.)
Flue Terminal
Snow
drift