36
Flue collar of water heater
Center line of the flue terminal
200 to 245
142
142
Screw holes (4)
(7.2 mm diameter and 35 to 40 mm depth).
160 mm diameter hole for the flue terminal sleeve
1) Determine the flue terminal installation location and make a 160 mm diameter hole in the wall for
the sleeve and 7.2 mm diameter holes for the screws to hold the sleeve.
Remove this screw
and slide out the
external cylinder.
Slide out the external cylinder
until it is flush with the external wall
and replace the screw.
2) Adjust the sleeve length to fit the wall thickness. Install the sleeve with the
symbol on the top side.
Rounded wood
screw
Sleeve
Wall anchor
160 mm dia.
Waterproof the clearance
with a high temperature sealant
3) Waterproof the clearance between the sleeve and
wall with a high temperature sealant.
Sleeve
Waterproof the clearance
with a high temperature
sealant.
This symbol should
be on the top
15-2-4. Flue Terminal Installation Procedure
* When drilling, take care not to damage electric
wiring, or gas or water piping in walls.
(L)WH42̲56(33̲38)̲E
05.10.4, 1:41 PM