Installation Clearances
Before installing, check for the following:
The appliance must be installed in a suitably ventilated room, in accordance with the regulations
in force.
Install in accordance with relevant building and mechanical codes, as well as any local, state or
national regulations.
Item
Distance from combustibles
• Maintain the following clearances
from both combustible and
non-combustible materials.
• There must be a clearance of 600mm or
more in front of the flue terminal.
• This restriction will not be applied to an
area where an effective shield makes a
clearance of 600mm or more in front of
the exhaust outlet.
Check
Illustration
Caution
• If possible, leave 200mm or more on either
side of the unit to facilitate inspection.
• If possible, leave 600mm or more in front
of the unit to facilitate maintenance and
service if necessary.
Securing of space for
repair/inspection
600mm
or more
200mm
or more
Outdoor Clearances to Opening
into Any Building
Distance from
the top surface
Distance from
the side
45 mm
or more
45 mm
or more
Consult the flue
manufacturer for
clearances
300mm
or more
300mm
or more
300mm
or more
There must be no
building opening
within this area.
300mm
or more
Flue Terminal
200mm
or more