63
MN024-010
TFAM
Case B
Fibre optic DL troubleshooting
(The following procedure is summarized by the fl ow-chart in Fig. 3.3.14c)
1. Check to see if there are any points in which fi bres are experiencing a short radius of
curvature. In these cases, rearrange the optical path in order to avoid sharp bends (if
necessary, replace the optical cable with a longer one). If the TFLN red LED switches off,
troubleshooting has been successfully carried out. Otherwise, follow the next steps.
2. Check to see if SC-APC connectors are properly installed at both fi bre ends. In case
they are not, replug
the SC-SPC connectors to adapters. If the TFLN red LED switches off,
troubleshooting has been successful. Otherwise, follow the next steps.
3. Disconnect the optical fi bre and clean it at both ends, then clean the SC-APC ports on
both the TFLN and the Remote Unit. Re-connect the fi bre to relevant ports after cleaning.
If it hasn’t made the TFLN red LED switch off, follow the next steps.
4. Disconnect the optical SC-APC connector from the Remote Unit’s DL port, and measure
the output power POUT(DL) at the corresponding fi bre end. Then, go to the TFLN side,
disconnect the optical SC-APC connector from the TFLN DL port and measure the input
power PIN(DL) coming out of the TFLN DL port. Calculate the DL fi bre attenuation ADL as
ADL [dB] = PIN(DL) – POUT(DL)
a. If ADL > 4dB, then there are problems with the fi bre optic cable. Replace it with a
new one.
b. If ADL < 4dB, the troubleshooting procedure has not identifi ed the problem. Refer
to the Supervision System or contact assistance.
Summary of Contents for ION-B Series
Page 1: ...IONTM B Series User Manual rel 24 10...
Page 2: ......
Page 9: ...9 MN024 010...
Page 10: ...10 ION B User Manual 1 Introducing ION B...
Page 15: ...15 MN024 010...
Page 16: ...16 ION B User Manual 2 Equipment Overview...
Page 28: ...28 ION B User Manual...
Page 29: ...29 MN024 010 3 TFAx Remote Unit...
Page 32: ...32 ION B User Manual TFAM Case A...
Page 40: ...40 ION B User Manual TFAM Case A Figure 3 2 9 Case A layout with waal anchor quotes...
Page 53: ...53 MN024 010 TFAM Case B Figure 3 3 9 Case B layout with wall anchor quotes...
Page 64: ...64 ION B User Manual TFAM Case R...
Page 69: ...69 MN024 010 TFAM Case R a b c Figure 3 4 5 Mounting the Case R Remote Unit Steps a c...
Page 71: ...71 MN024 010 TFAM Case R i l Figure 3 4 5 Mounting the Case R Remote Unit Steps i l...
Page 77: ...77 MN024 010 TFAM Case R2 a b c Figure 3 5 5 Mounting the Case R2 Remote Unit Steps a c...
Page 79: ...79 MN024 010 TFAM Case R2 i l Figure 3 5 5 Mounting the Case R2 Remote Unit Steps i l...
Page 91: ...91 MN024 010 TFAM Case F 1 3 2 3 1 Figure 3 6 4 Mounting the Case F Remote Unit Steps a b a b...
Page 92: ...92 ION B User Manual TFAM Case F Figure 3 6 4 Mounting the Case F Remote Unit Steps c d c d...
Page 98: ...98 ION B User Manual...
Page 99: ...99 MN024 010 4 Rack based Master Unit...
Page 100: ...100 ION B User Manual...
Page 112: ...112 ION B User Manual TPRF...
Page 126: ...126 ION B User Manual TFLN...
Page 154: ...154 ION B User Manual...
Page 155: ...155 MN024 010 5 Con guration Examples...
Page 163: ...163 MN024 010 6 Warning and Safety Requirements...
Page 172: ...172 ION B User Manual 7 TECHNICAL SUPPORT...
Page 175: ...175 MN024 010 Appendixes...