Andon KD-7965 Operation Manual Download Page 6

DN:KD-7965-SMSY01 V3.0   

                                                                                      Operation Guide 

 

Template version:1 

6/15 

   

The monitor, the batteries and the cuff, must be disposed of according to local regulations at the 

end of their usage. 

2. TOUCH SCREEN SWITCH 

Your  monitor  has  a  touch  screen  as  equipment.  Be  careful  not  to  touch  the  screen  by  mistake.  Keep  the 
touch switch in ―OFF‖ position when the monitor is not in use to avoid unintentional operation. Please keep 

the  touch  switch  in 

―ON‖ position to operate the monitor. The touch switch is in 

―ON‖ position,  press the  touch screen (START button or MEM  button),  you can 

hear the beep. 

3. CLOCK AND DATE ADJUSTMENT 

a.

 

Once you install the battery or turn off the monitor, it will enter Clock Mode, and LCD will display time 

and date. 

See picture 3.

 

 

 

 

 

 

         

Picture 3                  Picture 3-1                  Picture 3-2                  Picture 3-3                Picture 3-4

 

b.

 

While  the  monitor  is  in  Clock  Mode,  pressing  both  the  ―START‖  and  ―MEM‖  button  simultaneously 

(touch  screen  switch  in  ON  position),  the  month  will  blink  at  first.

  See  picture  3-1.

  Press  the  button 

―START‖ repeatedly, the day, hour and minute will blink in turn. 

See picture 3-2 & 3-3 & 3-4. 

While the 

number  is  blinking,  press  the  button  ―MEM‖  to  increase  the  number.  Keep  on  pressing  the  button 

"MEM", the number will increase fast. 

c.

 

You can turn off the monitor by pressing ―START‖ button when the minute is blinking, then the time and 

date is confirmed. 

d.

 

The monitor will turn off automatically after 1 minute of no operation, with the time and date unchanged. 

e.

 

Once you change the batteries, you should readjust the time and date. 

4. VOICE SETTING 

a.  Ensure the touch screen switch in ON position. 

b.  Voice language setting: In clock mode, you can select the voice language by keeping on pressing the 

button ―MEM‖. Now LCD blink ―L0‖, ―L1‖, ―L2‖ … ―Ln‖

 (see picture 4 & 4-1)

 

circularly. ―L0‖ represents 

closing  voice  function,  ―L1‖  represents  language  1,  ―L2‖  represents  language  2,…,―Ln‖  represents 

language n, and so on. Yo

u can select the wanted language by releasing button ―MEM‖ when display 

the corresponding language code. 

Summary of Contents for KD-7965

Page 1: ...ERY LOADING 5 2 TOUCH SCREEN SWITCH 6 3 CLOCK AND DATE ADJUSTMENT 6 4 VOICE SETTING 6 5 CONNECTING THE CUFF TO THE MONITOR 7 6 APPLYING THE CUFF 7 7 BODY POSTURE DURING MEASUREMENT 7 8 TAKING YOUR BLO...

Page 2: ...level in the daytime while most people are awake and active Considering the above information it is recommended that you measure your blood pressure at approximately the same time each day Too freque...

Page 3: ...ssential performance IEC60601 1 2 2007 EN 60601 1 2 2007 AC 2010 Medical electrical equipment Part 1 2 General requirements for basic safety and essential performance Collateral standard Electromagnet...

Page 4: ...ressure exceed 300 mmHg or maintained above15 mmHg for longer than 3 minutes of the bladder may cause ecchymoma of your arm 7 Consult your physician if you have any doubt about below cases 1 The appli...

Page 5: ...s B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates u...

Page 6: ...ly touch screen switch in ON position the month will blink at first See picture 3 1 Press the button START repeatedly the day hour and minute will blink in turn See picture 3 2 3 3 3 4 While the numbe...

Page 7: ...ffed wrist in front of your body on a desk or table with the palm up If the cuff is correctly placed you can read the LCD display c The cuff must be neither too tight nor too loose Note Please refer t...

Page 8: ...y stored in the memory If the voice function is on it will announce the measurement result f After measurement the monitor will turn off automatically after 1 minute of no operation Alternatively you...

Page 9: ...r treatment by yourself Note It is not intended to provide a basis of any type of rush toward emergency conditions diagnosis based on the color scheme and that the color scheme is meant only to discri...

Page 10: ...on or strong electromagnetic interference Take out batteries for five minutes and then reinstall all batteries In Clock Mode no response when you press button The touch switch is in OFF position Pleas...

Page 11: ...iately qualified technical personnel to repair those parts of equipment which are designated repairably can be supplied 9 The monitor can maintain the safety and performance characteristics for a mini...

Page 12: ...omagnetic emissions The KD 7965 is intended for use in the electromagnetic environment specified below The customer or the user of the KD 7965 should assure that it is used in such an environment Emis...

Page 13: ...erial the relative humidity should be at least 30 Power frequency 50 60 Hz magnetic field IEC 61000 4 8 3 A m 3 A m Power frequency magnetic fields should be at levels characteristic of a typical loca...

Page 14: ...l situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular...

Page 15: ...r of transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7...

Reviews: