Andon KD-7965 Operation Manual Download Page 12

DN:KD-7965-SMSY01 V3.0   

                                                                                      Operation Guide 

 

Template version:1 

12/15 

       

Symbol for ―EUROPEAN REPRESENTATION‖ 

SN

               

Symbol for ―SERIAL NUMBER‖ 

           

Symbol for ―KEEP DRY‖ 

WARRANTY INFORMATION 

Only charge the cost of components and transport.   

SERVICE CENTER 

ANDON HEALTH CO., LTD. 

No. 3 Jinping Street, Ya An Road, Nankai District, Tianjin 300190, China. 

Tel: 86-22-60526081 

 

Lotus Global Co., Ltd. 

15 Alexandra Road, London UK, NW8 0DP 

Tel: +0044-20-75868010    Fax: +0044-20-79006187 

ELECTROMAGNETIC COMPATIBILITY INFORMATION 

Table 1 

For all ME EQUIPMENT and ME SYSTEMS 

Guidance and manufacture’s declaration - electromagnetic emissions 

The KD-7965 is intended for use in the electromagnetic environment specified below. 

The  customer  or  the  user  of  the  KD-7965  should  assure  that  it  is  used  in  such  an 

environment. 

Emissions test 

Compliance 

Electromagnetic environment - 

guidance 

RF emissions 

CISPR 11 

Group 1 

The  KD-7965  uses  RF  energy  only  for  its 

internal 

function. 

Therefore, 

its 

RF 

emissions  are  very  low  and  are  not  likely 

to  cause  any  interference  in  nearby 

electronic equipment. 

RF emissions 

CISPR 11 

Class B 

The  KD-7965  is  suitable  for  use  in  all 

establishments  other  than  domestic  and 

those  directly  connected  to  the  public 

low-voltage  power  supply  network  that 

supplies  buildings  used  for  domestic 

Harmonic emissions 

IEC 61000-3-2 

Not applicable 

Voltage fluctuations/ 

Not applicable 

Summary of Contents for KD-7965

Page 1: ...ERY LOADING 5 2 TOUCH SCREEN SWITCH 6 3 CLOCK AND DATE ADJUSTMENT 6 4 VOICE SETTING 6 5 CONNECTING THE CUFF TO THE MONITOR 7 6 APPLYING THE CUFF 7 7 BODY POSTURE DURING MEASUREMENT 7 8 TAKING YOUR BLO...

Page 2: ...level in the daytime while most people are awake and active Considering the above information it is recommended that you measure your blood pressure at approximately the same time each day Too freque...

Page 3: ...ssential performance IEC60601 1 2 2007 EN 60601 1 2 2007 AC 2010 Medical electrical equipment Part 1 2 General requirements for basic safety and essential performance Collateral standard Electromagnet...

Page 4: ...ressure exceed 300 mmHg or maintained above15 mmHg for longer than 3 minutes of the bladder may cause ecchymoma of your arm 7 Consult your physician if you have any doubt about below cases 1 The appli...

Page 5: ...s B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates u...

Page 6: ...ly touch screen switch in ON position the month will blink at first See picture 3 1 Press the button START repeatedly the day hour and minute will blink in turn See picture 3 2 3 3 3 4 While the numbe...

Page 7: ...ffed wrist in front of your body on a desk or table with the palm up If the cuff is correctly placed you can read the LCD display c The cuff must be neither too tight nor too loose Note Please refer t...

Page 8: ...y stored in the memory If the voice function is on it will announce the measurement result f After measurement the monitor will turn off automatically after 1 minute of no operation Alternatively you...

Page 9: ...r treatment by yourself Note It is not intended to provide a basis of any type of rush toward emergency conditions diagnosis based on the color scheme and that the color scheme is meant only to discri...

Page 10: ...on or strong electromagnetic interference Take out batteries for five minutes and then reinstall all batteries In Clock Mode no response when you press button The touch switch is in OFF position Pleas...

Page 11: ...iately qualified technical personnel to repair those parts of equipment which are designated repairably can be supplied 9 The monitor can maintain the safety and performance characteristics for a mini...

Page 12: ...omagnetic emissions The KD 7965 is intended for use in the electromagnetic environment specified below The customer or the user of the KD 7965 should assure that it is used in such an environment Emis...

Page 13: ...erial the relative humidity should be at least 30 Power frequency 50 60 Hz magnetic field IEC 61000 4 8 3 A m 3 A m Power frequency magnetic fields should be at levels characteristic of a typical loca...

Page 14: ...l situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular...

Page 15: ...r of transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7...

Reviews: