Adjusting the Danfoss variable
displacement pump pressure and the
main valve relief pressure on a PVG32 #
010
Pressure adjustment procedure
1. Adjust the pressure sensing pressure on the pump to 350 psi
•
Loosen screw #1
•
Check pressure on LS gauge
• If the pressure is lower than 350 psi tighten screw #2
• If the pressure is higher than 350 psi loosen screw #2
• Repeat step b and c, until you have 350 psi on the LS gauge
•Tighten screw #1