Protocol to inspect bad wired blowing up
the fuses # 003
35
When inserting a new fuses, if it burned immediatly, it is sign
that you have a cutted wired that might have been damaged
because it became loose, or a debris cutted it or the wire got
cutted by some movement of the Stackpro.
1. Disconnect the Touchscreen display harness and the
communication cable with the Stackpro
2. Put a new fuse. If it burned, your bad connection is located
between the tractor and your touchscreen display harness.
Inspect and fix it.
3. If the fuse dont blow, connect again the touchscreen
display harness to the Stackpro communication cable. It
will normally blow the fuse at that exact moment.
4. If it blow immediately, some sensors are powered directly
by the battery of the tractor, and those shall be the first to
be inspected.
5. See next page for susceptible sensor that you should
inspect the wiring.