![Anderson AV-9000 Instruction Manual Download Page 232](http://html1.mh-extra.com/html/anderson/av-9000/av-9000_instruction-manual_2941763232.webp)
Edition 3
Rev G
Section 11
11-7
CHART
Will place a dot on the inner or outer ring, whichever is selected for calibration
SCROLL
Will select either the inner or outer ring
UP
Will move the selected (inner or outer) ring position to the left and print a dot in the new
position without moving the chart.
DOWN
Will move the selected (inner or outer) ring position to the right and print a dot in the new
position without moving the chart.
RESET
Will move the chart 30 steps while not printing any dots
ESC
Will exit with no change to the calibration values
ENTER
Will exit with the new values being stored
Step 3
With INNER RING CALIBRATE on the upper display line, depress the
to view the current location of the
inner ring zero point. Use UP/DOWN to position the dot accordingly, use RESET to move the chart.
Step 4
D e p r e s s
the to toggle the upper display line to read OUTER RING CALIBRATE.
Step 5
D e p r e s s
the to view the current location of the outer ring zero point. Use UP/DOWN to position the dot
accordingly, use RESET to move the chart.
Step 6
D e p r e s s
the to save calibration values.
11.5 MILLIAMP OUTPUT CALIBRATION
This routine is used to adjust the mA Output(s) for span. A milliamp meter is required to perform this calibration.
Step 1
With mA OUTPUTS in the lower display line, depress the
and CAL WHICH mA OUTPUT
appears in the upper display line and 1 appears in the lower display line. To
change,
depress the , then the to desired output number, then depress .
Summary of Contents for AV-9000
Page 2: ......
Page 4: ......
Page 22: ......
Page 290: ...Appendix A Edition 3 Rev G A 2 FIGURE A 2 MOTHER BOARD J5 J6 J4 J7 J1 J3...
Page 293: ...Edition 3 Rev G Appendix A A 5 FIGURE A 5 MOTOR DRIVER BOARD J4B J5 J6 J1 J7 J4A J3 J2...
Page 295: ...Edition 3 Rev G Appendix A A 7 FIGURE A 7 TRANSMITTER POWER SUPPLY BOARD J3 TB2 TB1 TB3 TB4...