Edition 3
Rev G
Section 4
4-43
25. Press the
to advance to the next parameter, ALARM 4 SAMPLE PERIOD (only seen if Ax4 TYPE is
RATE).
26. Press the
to advance to the next parameter, ALARM 4 HYSTERESIS.
NOTE: If RATE Alarm is selected, Hysteresis equals RATE in units/TIME BASE.
Press the
to change, then
to
desired value, then press the
.
Ax4 SAMPLE PERIOD
10 SECONDS
Selections
1 to 9999 seconds
Note: Units correspond
to Units configured in
Process Variables.
P
R
O
C
E
S
S
V
A
R
I
A
B
L
E
S
Ax4 HYSTERESIS
3 units
Selections
±
999999
(decimal position = 0)
±
9.9999
(decimal position = 4)
Press the
to change, then
to
desired value, then press the
.