PortaSens
III
Portable Gas Leak Detector, Model D16
Operation and Maintenance Manual
Rev-A Feb 2018
- 13 -
OPERATION
The D16 features a touch-sensitive, color graphics display that is
organized into pages to configure and operate the device. The primary
operational information, consisting of the gas reading and alarm indicators,
appears on the “Main Display” page. Configuration settings, and other
operational displays, appear on pages accessed through the menu system by
touching the “Menu” button.
D16 pages are normally presented on a dark background. Pages
depicted below appear on a white, or light colored background to improve
readability.
Startup
Install a gas sensor module, connect the
sampling wand, and hold the “Wakeup”
switch down for one second.
D16 displays the pages shown below.
LCD and CPU revision levels and serial number.
Times out after four seconds.
Information about the currently installed sensor.
Times out in four seconds.
Main display shows gas reading, gas
temperature, alarm indicators, battery and
pump status, date, and time.
Figure 10 D16 startup displays.
LCD Rev 1.0
Model-Rev-S/N