![Analytic Systems BCD615 SERIES Installation & Operation Manual Download Page 5](http://html1.mh-extra.com/html/analytic-systems/bcd615-series/bcd615-series_installation-and-operation-manual_2940512005.webp)
5
Introduction
All new Current Mode switching design offers increased power and reliability in a compact
package. Extra input and output filtering reduce EMI to extremely low levels. Reliability
features include an input fuse, thermal shutdown, current limiting, reverse battery hookup
protection and output short circuit shutdown with automatic recovery. The output voltage is
easily adjusted 1.0 volts above or below the standard output voltage to accommodate special
charging requirements. High quality digital meters can be added (factory option) to allow
monitoring of output current and output voltage.
Specifications
Input Voltages
Nominal (ip)
24
48
72
Actual
** 20 – 35
** 40 – 60
** 65 – 90
Input Amps (max)
37.9
19.4
12.1
Input Fuse
3 x ATC15
1 x ATC25
1 x ATC20
Output Voltages
Nominal (op)
12
24
48
Float (Vdc)
13.6 ± 0.05V
27.2 ± 0.05V
54.4 ± 0.05V
Absorption (Vdc)
14.4
28.8
57.6
Charging Amps
40
20
10
Absorption to Float
6.0 Amps
3 Amps
1.5 Amps
Battery Size (Amp Hours)*
160 – 240
80 – 120
40 - 60
Output Adjust
± 1.0 Volts
Output Crowbar
16.0 ± 0.5 V
32 ± 1.0 V
63.9 ± 2.0 V
Equalize Voltage (Vdc)
15.5
31
62
Temperature Compensation
Coefficient
-30mV / o C
-60mV / o C
-120mV / o C
Output Fuses
ATC-40 x 2
ATC-30 x 2
ATC-15 x 2