Ax60+ Multi-Gas
Service Manual
Int. Approved
Document ref: P0159-803-11
September 2019
Page 40 of 62
Copyright © 2015 Analox Ltd. All Rights Reserved.
Commercial in Confidence
8.4.3
Relay 1 fail-safe (Displayed as Rly 1 fail-safe)
1]
Press and hold Cycle for at least 6 seconds. Then press Cycle five times to display
Central Config.
2]
Press Accept/Test, then press Cycle twice, press Accept/Test to display the Rly 1 fail-safe
screen
3]
Press Cycle to toggle Y or N, then press Accept/Test to confirm.
4]
Press Cancel repeatedly to return to system status screen
8.4.4
Relay 2 fail-safe (Displayed as Rly 2 fail-safe)
1]
Press and hold Cycle for at least 6 seconds. Then press Cycle five times to display
Central Config.
2]
Press Accept/Test, then press Cycle three times, press Accept/Test to display the Rly 2 fail-safe
screen
3]
Press Cycle to toggle Y or N, then press Accept/Test to confirm.
4]
Press Cancel repeatedly to return to system status screen