![Analog way Smart Quad SQD200 User Manual Download Page 19](http://html1.mh-extra.com/html/analog-way/smart-quad-sqd200/smart-quad-sqd200_user-manual_2940364019.webp)
Dimensions:
W 482 x D 330 x H 88 mm
19”W x 13”D x 3.50”H
Weight:
5 kg / 11 lbs
(Compatible with a Standard 19” rack, Height = 2 U)
Cooling air flow from right side to left side.
Max ambient operating temperature: < 40°C (< 104°F).
Operating temperature:
0 to +40°C / +32°F to +104°F
Storage temperature: -25 to +85°C / -13°F to +185°F
Operating humidity:
10 to 80% (non condensing)
Input voltage range:
100-240 VAC, 50/60 Hz
Typical consumption: 90 W
CE Compliancy, test following:
- EN 55022: 2006 / A1: 2007,
- EN 55024: 1998 / A1: 2001 / A2: 2003,
- EN 61000-3-2: 2006,
- EN 61000-3-3: 1995 / A1: 2001 / A2: 2005.
Safety, test following:
- IEC 60950-1: 2005,
- UL 60950-1: 2007,
- CAN/CSA-C22.2 NO. 60950-1.
Power supply: IEC/EN/UL/CSA 60950-1, internal, autoswitching
Mechanical (in carton): Vibration: IEC60068-2-64
Free fall: IEC60068-2-32, RoHS, WEEE
Environmental specifications