UG-169 

Evaluation Board User Guide

 

Rev. 0 | Page 8 of 12 

The 

Register Map Values

 window, accessed by selecting 

Register Map Window

 from the 

View

 menu, allows you to read 

registers (see Figure 10).  

0

91

71-

0

1

1

 

Figure 10. Register Map Window 

Help Menu 

Selecting 

Help

 from the 

Help

 menu opens the 

About AD9523

 

window, which contains information such as revision number, 
region information, and contact information. 

USING THE SOFTWARE TO CONTROL THE 
FUNCTIONAL BLOCKS OF AD9523 

Register W/R  

The 

Register W/R

 (write/read) section has three buttons and 

three check boxes. 

The 

WRITE

 button transfers the values stored in the evaluation 

software to the evaluation board. It blinks red when register 
values have changed. 

The 

READ

 button transfers the values stored in the evaluation 

board to the evaluation software.  

The 

UPDATE

 button issues an I/O update command by writing 

to the I/O update register.  

Selecting the 

All

 checkbox transfers all of the registers when the 

WRITE

 button is clicked. When this box is not selected, only 

the registers whose value has changed are written. 

Selecting the 

Auto

 checkbox adjacent to the 

WRITE

 button 

forces the evaluation software to write the register changes to 
the evaluation board automatically when they occur. 

Selecting the 

Auto

 checkbox adjacent to the 

UPDATE

 box 

forces the evaluation software to issue an I/O update command 
whenever registers are written to the AD9523. 

SYNC, PD (Power Down), and RESET 

The SYNC, PD, and RESET buttons allow you to control the 
SYNC, PD, and RESET pins on the AD9523. 

Each button has three options: 

Strobe

Latch

, and 

Release

Strobe 

activates the pin, and then releases it. 

Latch

 holds the 

pin active until the 

Release

 command is issued. 

PLL 1 CONTROLS 

The PLL 1 box in the main window (see Figure 6) allows you to 
configure the PLL1 parameters. Clicking the 

PLL 1

 box in 

Figure 11 opens a window to allow configuration of PLL1 (see 
Figure 12 ). 

0

91

71

-0

12

 

Figure 11. PLL1 Box (in Main Window) 

Clicking each individual box in the 

PLL 1 Controls

 window 

opens a new window to allow configuration of that block (see 
Figure 13 for an example for the 

REF A Divider

 window).  

0

91

71-

01

3

 

Figure 12. PLL1 Control Box 

Reference (REF) Divider Window 

0

91

71

-0

14

 

Figure 13. Reference A or B Divider Window 

The REF (Reference) Divider window shown in Figure 13 is 
accessed by clicking the 

REF A Divider

 box in Figure 12.  

It allows you to set the reference divider. There is a 
corresponding window for both REF A and REF B dividers. 

           

Summary of Contents for AD9523

Page 1: ...ity allowing programming of almost any rational input output frequency ratio GENERAL DESCRIPTION This user guide describes the hardware and software of the AD9523 and AD9524 evaluation boards and incl...

Page 2: ...he Signal Connections 3 Bypassing the 6 V Wall Socket Power Supply 3 Using I2 C Serial Port Mode 4 Evaluation Board Software Setup 5 Installing the Software 5 Using the Software 5 Software Operation 6...

Page 3: ...erminated 50 to ground An amplitude setting of 6 dBm is sufficient 2 Connect an oscilloscope spectrum analyzer or other lab equipment to any of the OUTx SMA connectors on the right side of the board T...

Page 4: ...ss using Jumpers P5 and P6 see Figure 3 Note that setting P5 and P6 low is reserved for SPI mode 2 On the evaluation software select Configure Serial Port from the I O menu see the I O Menu section 3...

Page 5: ...nd connect the evaluation board to the PC 2 Double click AD9523 Eval Software to run the AD9523 evaluation software A hardware installation window appears Depending on whether the evaluation board was...

Page 6: ...r own window are outlined in this section From the main window the window for each functional block can be accessed by clicking the appropriate box When a subsection window closes after clicking OK th...

Page 7: ...to select which evaluation board the software controls see Figure 7 Click Refresh List to detect a recently connected evaluation board 09171 008 Figure 7 Select USB Device Window Selecting Configure...

Page 8: ...the evaluation software to write the register changes to the evaluation board automatically when they occur Selecting the Auto checkbox adjacent to the UPDATE box forces the evaluation software to is...

Page 9: ...box from the main window see Figure 16 w configuration of PLL2 see Figure 17 g the CHARGE PUMP box i This window is most often used to vary the charge pump current PLL 2 CONTROLS Clicking t opens a w...

Page 10: ...o vary the phase offset by changing the phase offset bits setting under the Divider Phase box in Figure 20 However for the new phase to take effect the SYNC signal must be toggled by clicking the SYNC...

Page 11: ...PROM Control window is shown in Figure 25 is accessed by clicking the EEPROM button near the lower left corner of the main window To store the current register settings of the AD9523 to the EEPROM cli...

Page 12: ...grants to Customer a free limited personal temporary non exclusive non sublicensable non transferable license to use the Evaluation Board FOR EVALUATION PURPOSES ONLY Customer understands and agrees t...

Reviews: