Installation
20
RE-DM4 and RE-DM6 RADIA Eclipse Dimmer Modules
RDA-ENC6B 120 VAC single phase line input
FIG. 17 shows a 120 VAC single-phase (2 W + G) wiring diagram for the RDA-ENC6B line input
terminal block.
RDA-ENC6B 120/240 VAC line input (single phase)
FIG. 18 shows a 120/240 VAC single-phase (3 W + G) wiring diagram for the RDA-ENC6B line input
terminal block.
FIG. 17
RDA-ENC6B 120 VAC single-phase (2 W + G) wiring diagram
FIG. 18
RDA-ENC6B 120/240 VAC single-phase (3 W + G) wiring diagram