Working With Properties
122
TPDesign4 Touch Panel Design Software (v2.10 or higher)
Level Control Parameters
The Level Control Type options allow General and Multi-State General buttons to directly control a level
without the need for NetLinx code. Select a level control type for the selected button (Absolute, Relative
or None):
Absolute
: The button acts like a preset and sets the level to the desired value.
Relative
: The button increments or decrements the current level value by a fixed amount.
These options require the following additional parameters to be defined:
Programming Properties (Cont.)
Range High
Set the top of the bargraph/joystick range (0-255).
Bargraph and Joystick buttons only.
Range Inverted
Travel top to bottom or right to left (depending on the Direction setting, default =
Off).
Bargraph and Joystick buttons only.
Range Low
Set the bottom of the bargraph/joystick range (0-255).
Bargraph and Joystick buttons only.
Range Time Down
Specify the amount of time (in 1/10th seconds) it will take for the bargraph to go
from the top to the bottom of the specified range (default = 2). It is not applicable
if the Level Function property is set to "
display only
".
Range Time Up
Specify the amount of time (in 1/10th seconds) it will take for the bargraph to go
from the bottom to the top of the specified range (default = 2). It is not applicable
if the Level Function property is set to "
display only
".
String Output
Specify the output string sent to the master on button push. Click the browse but-
ton (...) to open the Enter Text dialog. Enter the output string and click OK (or
Cancel to exit without saving).
String Output Port
Select or enter the port to which the output string will be applied.
Level Control Parameters
Level Code
Select or enter the level code sent to the master on the selected port. Select Auto-
Assign to automatically assign the level code to this button.
Level Control Repeat
This value determines the repeat time (in 1/10th-second increments) for relative
level control.
For example, if this value is set to 10, the user can hold the button down for one
second to cause the level to raise or lower repeatedly (according to the specified
Level Control Value) without having to press the button each time.
Relative Level Control only.
Level Control Value
For Absolute level control, this value determines the level value that will be recalled
by this button. For Relative level control, this value determines the amount of
adjustment relative to the current level resulting from this button. For relative level
control, this value can be entered as a positive integer (to raise the relative level
setting) or a negative integer (to lower the relative level setting).
Level Port
Select or enter the port to which the Level code will be applied. Select 0 (Setup port)
or 1 as the level port for this button.
Range High
Set the top of the level range (0-255).
Range Low
Set the bottom of the level range (0-255).
Range Time Down
Set the time (in 1/10th-second increments) that it takes to ramp from the top to the
bottom of the specified range (default = 2).
Range Time Up
Set the time (in 1/10th-second increments) that it takes to ramp from the bottom to
the top of the specified range (default = 2).
Summary of Contents for Modero NXD-1200VG
Page 20: ...xviii TPDesign4 Touch Panel Design Software v2 10 or higher Table of Contents ...
Page 130: ...List Box Buttons 110 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Page 160: ...Working With States 140 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Page 166: ...Working With Function Codes 146 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Page 174: ...Colors and Palettes 154 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Page 186: ...Animations and Tweening 166 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Page 208: ...Working With Templates 188 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Page 236: ...File Transfer Operations 216 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Page 248: ...Program Preferences 228 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Page 266: ...Appendix B G4 PanelBuilder 246 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Page 272: ...Appendix C TakeNote 252 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Page 273: ...Appendix C TakeNote 253 TPDesign4 Touch Panel Design Software v2 10 or higher ...