Upgrading the Firmware
72
4" Color Touch Panels with Audio
8.
Select the
Enable Online Tree
option to view the Connected devices from within the Project
Navigator window. The next step is to set the System value.
9.
After the Communication Verification dialog window verifies active communication between
the PC, the Master and the CP4/A, verify the touch panel appears in the Online tab of the
Project Navigator window (FIG. 39).
10.
Right-click on the touch panel and select Properties to confirm the on-board firmware.
11.
Select
Tools
>
Firmware > Download to Axcess Device
, from the Main menu, to open the
Communication Settings dialog box.
12.
Click Browse to navigate to the directory containing the firmware files. Once a directory
containing one or more TSK files is specified, a list of available TSK files is displayed in the
upper table in this dialog (FIG. 40 on page 73).
13.
Press the
Settings
button, from the Download to device via section, to enter the IP Address
information of the NetLinx Master being updated.
14.
Click
OK
when done setting the parameters.
15.
Click
Query Online Devices
to populate the on-line device list.
16.
Select the target AXlink device from the list of online devices in the lower-left table.
17.
Click
Download
to open the Confirm Communication Settings dialog, where you can review
and confirm your Comm Settings and Target Device information before the download begins.
FIG. 38
Communication Setting tab
FIG. 39
Sample NetLinx Project Navigator window
Enter an IP Address
Download the latest firmware file from AMX.COM > Tech Center > Downloadable
FIles > Firmware Files > AXD-CP4/A, AXT-CP4/A. Then Download the TSK file to
your computer.