![AMX AutoPatch CP-10 Instruction Manual Download Page 16](http://html.mh-extra.com/html/amx/autopatch-cp-10/autopatch-cp-10_instruction-manual_2937676016.webp)
Installing a CP-10 Remote Control Panel
13
CP-10 Instruction Manual
Connecting to AMX AutoPatch Matrix Switcher
Communication Cable Requirements
Two-conductor, 20 AWG, 7/28 strand cable with a drain wire or shield, such as Alpha 2412C
(customer supplied)
Maximum length of cable: 1,000 ft. (305 m) total, including linked panels
AMX AutoPatch pigtail (provided)
To connect a CP-10 Remote to an AMX AutoPatch Matrix Switcher:
1.
Attach the two wires of the AMX AutoPatch pigtail to the communication cable.
2.
On the rear of the panel, plug the AMX AutoPatch pigtail into the Comm Link connector (FIG. 5).
3.
On the matrix switcher’s CPU, unplug the REMOTE (XNNet) connector (for REMOTE connector
location, see the matrix switcher documentation).
4.
Loosen the two outer screws on the connector.
5.
Insert the two wires from the CP-10 Remote into the two outer slots of the REMOTE connector on
the matrix switcher, leaving the center slot empty (FIG. 6).
Note that either wire can go into either of the outer slots.
6.
Tighten the screws and plug the connector back into the CPU.
FIG. 5
Plug pigtail into the Comm Link
FIG. 6
Insert wires into REMOTE connector on enclosure
AutoPatch pigtail (provided)
Comm cable (customer supplied)