![AMX AutoPatch CP-10 Instruction Manual Download Page 15](http://html.mh-extra.com/html/amx/autopatch-cp-10/autopatch-cp-10_instruction-manual_2937676015.webp)
Installing a CP-10 Remote Control Panel
12
CP-10 Instruction Manual
Installing a CP-10 Remote Control Panel
This chapter covers rack installation for the CP-10 Remote Panel (FG1090-216), as well as instructions
for linking the panel to an enclosure. When the installation is complete, execute a test switch to make
sure the system is working properly (see page 15).
General Specifications
Rear View
Parameter
Value
Cable for XNNet
Communications
Two-conductor, 20 AWG, 7/28 strand cable with a drain wire or shield, such
as Alpha 2412C (customer supplied)
Maximum length of cable: 1000 ft. (305 m) total, including linked panels
Power
+7 VDC to +12 VDC @ 500 mA
Operational Temperature
32° F to 110° F (0° C to 43° C)
Humidity
0 to 90% non-condensing
Dimensions
1.0 in. (2.54 cm) depth
18.9 in. (48.0 cm) width with mounting ears
5.2 in. (13.21 cm) height, 3 RU
Weight
Approximately 2 lb (0.91 kg) per panel
FIG. 4
Rear view of CP-10 Remote Panel
Power connector
Comm Link connector