Installation
7
8.5" Black and White Touch Panels
2.
Carefully insert a flat-blade screwdriver into the release slot on the touch panel’s faceplate and
remove the engraved overlay.
3.
Lay the touch panel facedown on a soft cloth and remove the screws from the low-profile
Backbox; remove the Backbox and discard.
4.
Place the BB-TP2 into the cutout and mark the threaded insert positions, as shown in FIG. 5.
5.
Remove the BB-TP2 and drill four #6-32 insert holes. Then, place a threaded insert (or screw
anchor) into each hole.
6.
Disconnect the AXlink connector from the Central Controller. Then, disconnect the optional
RS-232 wiring from the external RS-232 device connected to the touch panel.
7.
Remove one or more knockouts to accommodate the wiring as required.
8.
Thread the incoming AXlink and RS-232 wiring through the BB-TP2 knockouts. Refer to
the
Wiring the Touch Panel
section on page 8 for pinout descriptions.
9.
Fasten the BB-TP2 to the plasterboard using the expansion screws supplied with the enclosure.
10.
Connect the AXlink and RS-232 wiring to the touch panel.
11.
Test the connection by reconnecting the AXlink connector to the Central Controller and the
optional RS-232 wiring to the source equipment. The panel beeps power-up. Before
continuing, disconnect all connections until panel installation is complete.
12.
Disconnect the above connections until the installation of the panel is complete.
13.
Fasten the touch panel to the BB-TP2 with the #6-32 screws supplied.
14.
Place the Decor-style faceplate onto the bezel. You can also secure the Decor faceplate to the
bezel using the four Phillips flathead security screws.
15.
Remove the backing from the adhesive tape strips. Once attached to the faceplate, the security
screws cannot be replaced without removing the overlay.
16.
Press the engraved overlay onto the faceplate.
17.
Reconnect the AXlink wiring to the Central Controller and RS-232 wiring (optional) to the
external RS-232 device. The touch panel will beep on power-up.
Rack-mount panel (AXM-LC/PB)
1.
Thread the incoming AXlink and optional RS-232 wiring through the opening in the
equipment rack. Disconnect the AXlink connector from the Central Controller and the optional
RS-232 connector from the external RS-232 device connected to the touch panel.
2.
Insert the touch panel into the equipment rack. Line up the top-left and bottom-right screw
holes and tighten the #6-32 screws. Then, tighten the bottom-left and top-right screws.
3.
Connect the AXlink and RS-232 wiring (optional) to the touch panel. Refer to the
Wiring the
Touch Panel
section for more information. The touch panel will beep on power-up.