Leave the product in its original packing box until you are ready to install.
Leave connector sealing caps in place until the optimizers are ready to be
connected to the PV string. The plugs protect the optimizer from water and debris
ingress.
Do NOT lift, carry, or otherwise handle the optimizers by their connectors.
Do NOT transport optimizers that are removed from packaging. If the original
packaging is no longer available, use a similar box to protect the connectors and
heat sink fins.
Steps
1.
Read all warning, caution, and notice statements for this section.
2.
Mount the String Optimizer following the
3.
Ground the String Optimizer according to your local codes. Use one of the two
grounding studs provided on the optimizer, a listed bonding washer, or another
method as required. Optimizer coating is 4 mil (0.1 mm).
4.
Verify that the optimizer is adequately grounded using continuity tester.
Figure 9: Ampt String Optimizer mounted and grounded