Copyright 2021 Ampt LLC.
All rights reserved.
27
V600-12 String Optimizer Platform
Installation Manual: 57070013-1 H
Connecting the Output
1.
Read all warning, caution, and notice statements for this section.
2.
Make sure you have completed all the steps in the
3.
Follow your safety procedures and protocols to ensure the output cables are
appropriately terminated and not under load.
4.
If the output cable is already energized (not isolated), verify that the optimizer
output voltage and output cable share the same potential and polarity.
5.
Connect the appropriate cables to the output of the String Optimizer.
Figure 15: Connecting the output connectors
6.
Ensure that the locking mechanisms on all connectors are fully engaged.
7.
Manage wires to prevent lateral strain on connectors and avoid movement of the
connecting wires at all times. Pay special attention when in-line fuses are used
and/or when mounted on a tracker.
Figure 16: Verify that the connectors are fully engaged
Use the polarity markings
on the optimizer faceplate
to avoid damaging the unit.
!
Ensure locking mechanisms on
all connectors are fully engaged
Manage wires to prevent lateral strain on
connectors and avoid movement of the
connecting wires at all times. Pay special
attention when in-line fuses are used
and/or when mounted on a tracker.