10.2 Technical data Temposonics
®
RH5
Output
Interface
Ethernet POWERLINK
Data protocol
POWERLINK V2
Measured value
Position, velocity/option: Simultaneous multi-position and multi-velocity measurements up to 30 magnets
Measurement parameters
Resolution: Position
0.5…100 µm (selectable)
Cycle time
Stroke length
≤ 50 mm
≤ 715 mm
≤ 2000 mm
≤ 4675 mm
≤ 7620 mm
Cycle time
250 µs
6
500 µs
1000 µs
2000 µs
3200 µs
Linearity deviation
7
Stroke length
≤
500 mm
>
500 mm
Linearity deviation
≤ ±50 µm
< 0.01 % F.S.
Optional internal linearity: Linearity tolerance
(applies for the first magnet for multi-position measurement)
Stroke length 25…300 mm 300…600 mm 600…1200 mm
typical
± 15 µm
± 20 µm
± 25 µm
maximum
± 25 µm
± 30 µm
± 50 µm
Repeatability
< ±0.001 % F.S. (minimum ±2.5 μm) typical
Hysteresis
< 4 µm typical
Temperature coefficient
< 15 ppm/K typical
Operating conditions
Operating temperature
−40…+85 °C (−40…+185 °F)
Humidity
90 % relative humidity, no condensation
Ingress protection
IP67
(connectors correctly fitted)
Shock test
150 g/11 ms, IEC standard 60068-2-27
Vibration test
30 g/10…2000 Hz, IEC standard 60068-2-6 (excluding resonant frequencies)/
RH5-J: 15 g/10…2000 Hz, IEC standard 60068-2-6 (excluding resonant frequencies)
EMC test
Electromagnetic emission according to EN 61000-6-3
Electromagnetic immunity according to EN 61000-6-2
The RH5 sensors fulfill the requirements of the EMC directives
2014/30/EU, UKSI 2016 No. 1091 and TR CU 020/2011
Operating pressure
350 bar (5076 psi)/700 bar (10,153 psi) peak (at 10 × 1 min) for sensor rod/RH5-J: 800 bar (11,603 psi)
Magnet movement velocity Any
Design/Material
Sensor electronics housing Aluminum (painted), zinc die cast
Sensor flange
Stainless steel 1.4305 (AISI 303)
Sensor rod
Stainless steel 1.4306 (AISI 304L)/RH5-J: Stainless steel 1.4301 (AISI 304)
RoHS compliance
The used materials are compliant with the requirements of EU directive 2011/65/EU and
EU regulation 2015/863 as well as UKSI 2022 No. 622
Stroke length
25…7620 mm (1…300 in.)/RH5-J: 25…5900 mm (1…232 in.)
Mechanical mounting
Mounting position
Any
Mounting instruction
Please consult the technical drawings on
Electrical connection
Connection type
2 × M12 female connectors, 1 × M8 male connector
2 × M12 female connectors, 1 × M12 male connector
Operating voltage
+12…30 VDC
±
20 % (9.6…36 VDC)
Power
consumption
Less than 4 W typical
Dielectric strength
500 VDC (DC ground to machine ground)
Polarity protection
Up to −36 VDC
Overvoltage protection
Up to 36 VDC
6/
Minimum cycle time for multi-position measurements (number of magnets ≥ 2): 400 µs
7/
With position magnet # 251 416-2
Temposonics
®
R-Series
V
POWERLINK
Operation Manual