Temposonics
®
R-Series
V
POWERLINK
Operation Manual
I 53 I
Table 3: Index 6010, 6301, 6302, 6310, 6311, 6312, 6313, 6320, 6321, 6322, 6323, 6330, 6331, 6332, 6333
Index Subindex
Name
Object type
Attribute
Data type
Description
6010
Preset values for multi-sensor devices
Array
The preset can be set for up to 30 magnets.
0
Number of entries
Variable
ro
Unsigned8
1…30
Preset for 1…30 magnets
Variable
rw
Integer32
6301
CAM enable register
Array
Via the “CAM enable register” the CAM channels can be enabled:
• Bit value 0: CAM inactive
• Bit value 1: CAM active
It can be set for up to 30 magnets.
0
Number of entries
Variable
ro
Unsigned8
1…30 CAM enable register for 1…30 magnets
Variable
rw
Unsigned8
6302
CAM enable polarity
Array
With “CAM enable polarity”, the polarity of each CAM can be definated.
If the polarity bit of a CAM is set, the current CAM state will be inverted.
It can be set for up to 30 magnets.
0
Number of entries
Variable
ro
Unsigned8
1…30 CAM enable polarity for 1…30 magnets
Variable
rw
Unsigned8
6310
CAM
1 low limit
Array
This object determines the lower limit of position for CAM 1.
It can be set for up to 30 magnets.
0
Number of entries
Variable
ro
Unsigned8
1…30
CAM 1 low limit for 1…30 magnets
Variable
rw
Integer32
6311
CAM
2 low limit
Array
This object determines the lower limit of position for CAM 2.
It can be set for up to 30 magnets.
0
Number of entries
Variable
ro
Unsigned8
1…30
CAM 2 low limit for 1…30 magnets
Variable
rw
Integer32
6312
CAM
3 low limit
Array
This object determines the lower limit of position for CAM 3.
It can be set for up to 30 magnets.
0
Number of entries
Variable
ro
Unsigned8
1…30
CAM 3 low limit for 1…30 magnets
Variable
rw
Integer32
6313
CAM 4 low limit
Array
This object determines the lower limit of position for
CAM
4.
It can be set for up to 30 magnets.
0
Number of entries
Variable
ro
Unsigned8
1…30
CAM 4 low limit for 1…30 magnets
Variable
rw
Integer32
6320
CAM 1 high limit
Array
This object determines the upper limit of position for
CAM
1.
It can be set for up to 30 magnets.
0
Number of entries
Variable
ro
Unsigned8
1…30
CAM 1 high limit for 1…30 magnets
Variable
rw
Integer32
6321
CAM 2 high limit
Array
This object determines the upper limit of position for
CAM
2.
It can be set for up to 30 magnets.
0
Number of entries
Variable
ro
Unsigned8
1…30
CAM 2 high limit for 1…30 magnets
Variable
rw
Integer32
6322
CAM 3 high limit
Array
This object determines the upper limit of position for
CAM
3.
It can be set for up to 30 magnets.
0
Number of entries
Variable
ro
Unsigned8
1…30
CAM 3 high limit for 1…30 magnets
Variable
rw
Integer32
6323
CAM 4 high limit
Array
This object determines the upper limit of position for
CAM
4.
It can be set for up to 30 magnets.
0
Number of entries
Variable
ro
Unsigned8
1…30
CAM 4 high limit for 1…30 magnets
Variable
rw
Integer32
6330
CAM 1 hysteresis
Array
Via this parameter the delay setting of the switch points for
CAM
1 can be
set. It can be set for up to 30 magnets.
0
Number of entries
Variable
ro
Unsigned8
1…30
CAM 1 hysteresis for 1…30 magnets
Variable
rw
Integer32
6331
CAM 2 hysteresis
Array
Via this parameter the delay setting of the switch points for
CAM
2 can be
set. It can be set for up to 30 magnets.
0
Number of entries
Variable
ro
Unsigned8
1…30
CAM 2 hysteresis for 1…30 magnets
Variable
rw
Integer32
6332
CAM 3 hysteresis
Array
Via this parameter the delay setting of the switch points for
CAM
3 can be
set. It can be set for up to 30 magnets.
0
Number of entries
Variable
ro
Unsigned8
1…30
CAM 3 hysteresis for 1…30 magnets
Variable
rw
Integer32
6333
CAM 4 hysteresis
Array
Via this parameter the delay setting of the switch points for
CAM
4 can be
set. It can be set for up to 30 magnets.
0
Number of entries
Variable
ro
Unsigned8
1…30
CAM 4 hysteresis for 1…30 magnets
Variable
rw
Integer32