background image

INTRODUCTION

CONTENTS

Introduction and contents

Parts identifications 

Installation schematic

Single unit installation

Cascade

Connecting the unit

Rack installation

Input source

Output audio

Remote panel

Remote trigger 

RS485

EP1200A connection

EM / AC contact

Message player (MR1301)

Setting up 

Main Menu

Routing

Audio

Unit setting

Monitor Output

Siren

Save & Exit

Technical specifications

Warranty

page 2

MxP2288 | MatriMix Paging

2

3

5

6

17
18

MxP2288 succeeded its predecessor MxP2188 which had been running for over a decade long. Various features are introduced to fulfill the sophisti-

cated demands of today's PA installation. Apart from the value added features, operating and installation works has been greatly simplified. It is 

undeniable an advanced and user friendly product ever produced by Amperes.

Be it a standalone installation or a networked ( LAN ) setup, MxP2288 shall outshine others in its class, which we learn and applied all feedback, 

making it a truly outstanding equipment worth invested in. It is suitable for both commercial and residential application.

Among prominent features as compared to previous version are :

                - 12 x 8 matrix configuration

                - Powerful processor

                - Zone Expansion in cascade mode

                - Flexible audio source

                - Fail safe operation

                - Network (LAN) ready

                - Prioritised audio routing

                - Output with individual VBT

7

7

7

8

8

8

8

8

9

9

10

10

10

Remote paging mic

24V DC power input

Cascading the unit

11

12

12

13

13

13

14

Device setup via browser

14

Ethernet Port

Summary of Contents for MxP2288

Page 1: ...installation and operation INSTRUCTION MANUAL 12 x 8 Ethernet Matrix Controller www ampereselectronics com malaysia amperes M P2288 VOLUME 12 x 8 EHTERNET MATRIX CONTROLLER amperes MENU ENTER PREV NEX...

Page 2: ...om the value added features operating and installation works has been greatly simplified It is undeniable an advanced and user friendly product ever produced by Amperes Be it a standalone installation...

Page 3: ...8 CH 7 CH 8 CH 7 CH 6 CH 5 CH 4 CH 3 CH 2 CH 1 CASCADE OUT EP1200 CONNECTION 24V DC IN 1 A REMOTE PANEL 1 REMOTE PANEL 2 CH4 CH1 CH2 CH3 COM NO COM NO COM NO COM NO CONFIGURABLE REMOTE TRIGGER EM AC C...

Page 4: ...ET PORT Connectivity to network switch Audio output is balanced line level signal Each individual ouput can have its level preset at the front panel including the bass and treble control The external...

Page 5: ...Rack Mount VC LS4600 Line Surveillance Wifi Audio Streaming Controls Tab smart phone PC Paging PC Audio Streaming Controls AX3800 Duty Amp Duty Amp Audio 100V Out 1 Out 8 MR1301 EP1200A Paging Mic Inp...

Page 6: ...ORMAL 5 6 4 3 2 1 6 AMP NUMBER 7 8 PILOT TONE STANDBY AMP FAULT Speaker Speaker AX3800 Duty Amp Duty Amp Audio 100V Audio 100V Amp Duty Amp Audio 100V Audio 100V Amp Audio 100V PC Tablet Smartphone Sl...

Page 7: ...utput is available as balanced line level through XLR jack It can be fed directly to power amplifiers or through intermediate equipment such as AX3800 auto amplifier changeover panel as show CH 6 CH 8...

Page 8: ...24V DC IN 1 A REMOTE PANEL 1 REMOTE PANEL 2 CH4 CH1 CH2 CH3 COM NO COM NO COM NO COM NO CONFIGURABLE REMOTE TRIGGER EM AC CONT NO RS485 A B ETHERNET PORT MESSAGE PLAYER IN LINE BAL REMOTE PAGING MIC...

Page 9: ...ING MIC M P 2288 12 x 8 EHTERNET MATRIX CONTROLLER x EP1200 CONNECTION 24V DC IN 1 A REMOTE PANEL 1 REMOTE PANEL 2 CH4 CH1 CH2 CH3 COM NO COM NO COM NO COM NO CONFIGURABLE REMOTE TRIGGER EM AC CONT NO...

Page 10: ...T MESSAGE PLAYER IN LINE BAL All controller data ie input sources data paging mic etc are transmited through the cable to the next unit Maximum connectivity is 12 nos Each controller shall be assigned...

Page 11: ...wser shall be required Press ENTER MENU button to access the menus 2 AUDIO Routing of inputs to outputs 3 UNIT SETTING Output channel setting for Volume Bass and Treble 4 MONITOR OUTPUT Setting of uni...

Page 12: ...rce selection SELECT INPUT INPUT 1 8 DISABLED Next Use PREV or NEXT button to select the source to be routed to the channel selected eg Output 2 Enter Use PREV or NEXT to select Yes or No and continue...

Page 13: ...T 1 8 Enter Enter Return to Main Menu 5 SIREN MAIN MENU 5 SIREN ENABLE SIREN YES NO Enter Enter Return to Main Menu Use Next Prev button to select mode Enter Enter Enter To set the starting address of...

Page 14: ...for 2 minutes it shall automatically return to the main display without saving any changes DEVICE SETUP VIA BROWSER 1 Dashboard Sub menu Link the unit to network switch It is best using IE browser of...

Page 15: ...radio CE cast etc Stream port is the stream port of the server Default 3003 Paging Server To indicate the address of which the client is connected to for application in Amperes iPX5000 IP environment...

Page 16: ...e standalone or cascade Device name You can rename the device name Network configuration For configuration of IP address and its related ports Unless required you are recommended to change the IP addr...

Page 17: ...PCM ADPCM OGG MP3 WMA WAV Audio output 8 x balanced line output via XLR jacks Cascade link via flat cable Tone volume controls Bass 14 dB cut and boost 2 dB step Treble 14 dB cut and boost 2dB step Vo...

Page 18: ...the dealer for the period out of use of the unit moreover the warranty does not cover any damages which may be caused to people and things when using the product This warranty certificate is valid on...