MxP2288 | MatriMix Paging

Configuration 

 

12 x 8 matrix controller

Power source 

 

24V DC ; 1A 

Inputs channels 

 

8 mic / line level balanced signal via combo jacks

 

 

 

1 x emergency mic panel (EP1200A)

 

 

 

1 x message player (MR1301)

 

 

 

1 x paging mic (PD series)

 

 

 

1 x LAN music streaming (to be available)   

Input connections   

Combo jack;

 

 

 

Mic (XLR), phone (1/4” stereo phone jack) 

Input impedance 

 

Mic: 600 Ohm                   

 

 

 

Line: 10K Ohm balanced

Input sensitivity 

 

800mVrms (line level) and 350mVrms (mic level) 

Frequency response   

150Hz - 17 KHz (+/-3 dB at 1 KHz) with low cut 

Total harmonic distortion (THD)  0.10% 

 

LAN audio streaming  

16 - 48 KHz PCM (Browser Streaming)

 

 

 

128Kb/s CBR MP3 (PMX / iPX Music Streaming)

Paging audio streaming 

IMA ADPCM (16 KHz)

Digital format 

 

PCM / ADPCM / OGG / MP3 / WMA / WAV 

Audio output 

 

8 x balanced line output via XLR jacks

 

 

 

Cascade link via flat cable

Tone / volume controls 

Bass: +/-14 dB cut and boost (2 dB step)

 

 

 

Treble: +/-14 dB cut and boost (2dB step)

 

 

 

Volume: 0 dB to - 78.75 dB (1.25 dB / step)

Audio gain (max) 

 

+4 dB

Output audio monitoring  

Via front 3W speaker

Communication control 

RS485; 19.2 Kbps

User interface 

 

Direct web interface via LAN for PC and WIFI for  

   TAB 

and 

Phone

Remote controls 

 

Via PC / Tablet / Smartphone

Unit cascade control   

12 units / 96 output channels

Trigger port  

 

Message / Emergency Paging ( programmable )            

Priority controls 

 

BGM (Local source, iPX, browser  stream)    

   Paging 

   Message

 

 

 

Emergency Paging (highest priority) 

           

Fail safe feature 

 

Emergency paging bypass 

 

 

E/M override contact   

3A dry contact 

Dimensions (WxHxD)  

482 x 88 x 180 mm

Weight   

  

3.3 Kg

Note:

The above specifications are correct at time of printing but subjected to changes without prior notice due to product improvements.

Summary of Contents for MxP2288

Page 1: ...installation and operation INSTRUCTION MANUAL 12 x 8 Ethernet Matrix Controller www ampereselectronics com malaysia amperes M P2288 VOLUME 12 x 8 EHTERNET MATRIX CONTROLLER amperes MENU ENTER PREV NEX...

Page 2: ...om the value added features operating and installation works has been greatly simplified It is undeniable an advanced and user friendly product ever produced by Amperes Be it a standalone installation...

Page 3: ...8 CH 7 CH 8 CH 7 CH 6 CH 5 CH 4 CH 3 CH 2 CH 1 CASCADE OUT EP1200 CONNECTION 24V DC IN 1 A REMOTE PANEL 1 REMOTE PANEL 2 CH4 CH1 CH2 CH3 COM NO COM NO COM NO COM NO CONFIGURABLE REMOTE TRIGGER EM AC C...

Page 4: ...ET PORT Connectivity to network switch Audio output is balanced line level signal Each individual ouput can have its level preset at the front panel including the bass and treble control The external...

Page 5: ...Rack Mount VC LS4600 Line Surveillance Wifi Audio Streaming Controls Tab smart phone PC Paging PC Audio Streaming Controls AX3800 Duty Amp Duty Amp Audio 100V Out 1 Out 8 MR1301 EP1200A Paging Mic Inp...

Page 6: ...ORMAL 5 6 4 3 2 1 6 AMP NUMBER 7 8 PILOT TONE STANDBY AMP FAULT Speaker Speaker AX3800 Duty Amp Duty Amp Audio 100V Audio 100V Amp Duty Amp Audio 100V Audio 100V Amp Audio 100V PC Tablet Smartphone Sl...

Page 7: ...utput is available as balanced line level through XLR jack It can be fed directly to power amplifiers or through intermediate equipment such as AX3800 auto amplifier changeover panel as show CH 6 CH 8...

Page 8: ...24V DC IN 1 A REMOTE PANEL 1 REMOTE PANEL 2 CH4 CH1 CH2 CH3 COM NO COM NO COM NO COM NO CONFIGURABLE REMOTE TRIGGER EM AC CONT NO RS485 A B ETHERNET PORT MESSAGE PLAYER IN LINE BAL REMOTE PAGING MIC...

Page 9: ...ING MIC M P 2288 12 x 8 EHTERNET MATRIX CONTROLLER x EP1200 CONNECTION 24V DC IN 1 A REMOTE PANEL 1 REMOTE PANEL 2 CH4 CH1 CH2 CH3 COM NO COM NO COM NO COM NO CONFIGURABLE REMOTE TRIGGER EM AC CONT NO...

Page 10: ...T MESSAGE PLAYER IN LINE BAL All controller data ie input sources data paging mic etc are transmited through the cable to the next unit Maximum connectivity is 12 nos Each controller shall be assigned...

Page 11: ...wser shall be required Press ENTER MENU button to access the menus 2 AUDIO Routing of inputs to outputs 3 UNIT SETTING Output channel setting for Volume Bass and Treble 4 MONITOR OUTPUT Setting of uni...

Page 12: ...rce selection SELECT INPUT INPUT 1 8 DISABLED Next Use PREV or NEXT button to select the source to be routed to the channel selected eg Output 2 Enter Use PREV or NEXT to select Yes or No and continue...

Page 13: ...T 1 8 Enter Enter Return to Main Menu 5 SIREN MAIN MENU 5 SIREN ENABLE SIREN YES NO Enter Enter Return to Main Menu Use Next Prev button to select mode Enter Enter Enter To set the starting address of...

Page 14: ...for 2 minutes it shall automatically return to the main display without saving any changes DEVICE SETUP VIA BROWSER 1 Dashboard Sub menu Link the unit to network switch It is best using IE browser of...

Page 15: ...radio CE cast etc Stream port is the stream port of the server Default 3003 Paging Server To indicate the address of which the client is connected to for application in Amperes iPX5000 IP environment...

Page 16: ...e standalone or cascade Device name You can rename the device name Network configuration For configuration of IP address and its related ports Unless required you are recommended to change the IP addr...

Page 17: ...PCM ADPCM OGG MP3 WMA WAV Audio output 8 x balanced line output via XLR jacks Cascade link via flat cable Tone volume controls Bass 14 dB cut and boost 2 dB step Treble 14 dB cut and boost 2dB step Vo...

Page 18: ...the dealer for the period out of use of the unit moreover the warranty does not cover any damages which may be caused to people and things when using the product This warranty certificate is valid on...

Reviews: