51
Pneumatic Positioner 47224X
OMMGGP00185
Rev 5 – MAY 2019
5.4.1
Reverse the actuation
The action of the positioner can be changed to “Direct” or “Reverse” as
required.
CAUTION
Ensure the Actuator pistons are orientated to give the correct
direction of movement for changes in signal input pressure. Refer to
Section 4.4.2
Ensure the Valve is positioned over the port corresponding to zero
actuator pressure.
Refer to Fig 29.
Unscrew the four screws and remove the Positioner cover.
Fig 29
Cam reversal
Pull off the position indicator (not illustrated).
Unscrew and remove the lock screw.
Remove the rubber washer.
Summary of Contents for 02GGH
Page 2: ......
Page 8: ...8 Introduction Rev 5 MAY 2019 OMMGGP00185...
Page 14: ...14 System Overview Rev 5 MAY 2019 OMMGGP00185...
Page 23: ...23 Pneumatic Actuator 82046L OMMGGP00185 Rev 5 MAY 2019 Fig 5 Mode 32...
Page 24: ...24 Pneumatic Actuator 82046L Rev 5 MAY 2019 OMMGGP00185 Fig 6 Mode 23...
Page 25: ...25 Pneumatic Actuator 82046L OMMGGP00185 Rev 5 MAY 2019 Fig 7 Mode 12...
Page 26: ...26 Pneumatic Actuator 82046L Rev 5 MAY 2019 OMMGGP00185 Fig 8 Mode 21...
Page 27: ...27 Pneumatic Actuator 82046L OMMGGP00185 Rev 5 MAY 2019 Fig 9 Mode 13...
Page 28: ...28 Pneumatic Actuator 82046L Rev 5 MAY 2019 OMMGGP00185 Fig 10 Mode 31...
Page 41: ...41 Pneumatic Actuator 82046L OMMGGP00185 Rev 5 MAY 2019 Fig 22 Piston Orientation...
Page 58: ...58 PID Controller 8071D Rev 5 MAY 2019 OMMGGP00185...
Page 60: ...60 Pneumatic Indicator Controller SG80 Rev 5 MAY 2019 OMMGGP00185...
Page 79: ...79 Technical Data OMMGGP00185 Rev 5 MAY 2019 13 1 5 Valve Dimensions Fig 43 Valve Dimensions...