![AMOT 02GGH Installation, Operation And Maintenance Manual Download Page 30](http://html1.mh-extra.com/html/amot/02ggh/02ggh_installation-operation-and-maintenance-manual_2933821030.webp)
30
Pneumatic Actuator 82046L
Rev 5 – MAY 2019
OMMGGP00185
4.3
Operation
Under normal conditions, operation of the actuator is automatic and no
operator intervention is needed.
In the event of an actuator failure, the valve can be operated by a manual
override handle (if fitted as an option).
Remove and isolate the positioner air supply.
WARNING
When the clutch lever is operated the tension in the actuator return
springs is released, causing rapid movement of the valve. The valve
must indicate 0° (Direct acting) or 90° (Reverse acting) before
operation of the clutch lever to prevent possible injury and damage to
the gearbox.
Ensure the valve indicates 0° (Direct acting) or 90° (Reverse acting).
Pull out the spring loaded clutch lever (Fig 11).
Rotate the clutch lever clockwise until engagement takes place.
Turn the handle to position the valve.
Note
Anti-clockwise lever movement disengages manual override and returns the
system to automatic operation.
When under manual control, the valve remains locked in the last set
position.
Fig 11
Geared manual override operation
Summary of Contents for 02GGH
Page 2: ......
Page 8: ...8 Introduction Rev 5 MAY 2019 OMMGGP00185...
Page 14: ...14 System Overview Rev 5 MAY 2019 OMMGGP00185...
Page 23: ...23 Pneumatic Actuator 82046L OMMGGP00185 Rev 5 MAY 2019 Fig 5 Mode 32...
Page 24: ...24 Pneumatic Actuator 82046L Rev 5 MAY 2019 OMMGGP00185 Fig 6 Mode 23...
Page 25: ...25 Pneumatic Actuator 82046L OMMGGP00185 Rev 5 MAY 2019 Fig 7 Mode 12...
Page 26: ...26 Pneumatic Actuator 82046L Rev 5 MAY 2019 OMMGGP00185 Fig 8 Mode 21...
Page 27: ...27 Pneumatic Actuator 82046L OMMGGP00185 Rev 5 MAY 2019 Fig 9 Mode 13...
Page 28: ...28 Pneumatic Actuator 82046L Rev 5 MAY 2019 OMMGGP00185 Fig 10 Mode 31...
Page 41: ...41 Pneumatic Actuator 82046L OMMGGP00185 Rev 5 MAY 2019 Fig 22 Piston Orientation...
Page 58: ...58 PID Controller 8071D Rev 5 MAY 2019 OMMGGP00185...
Page 60: ...60 Pneumatic Indicator Controller SG80 Rev 5 MAY 2019 OMMGGP00185...
Page 79: ...79 Technical Data OMMGGP00185 Rev 5 MAY 2019 13 1 5 Valve Dimensions Fig 43 Valve Dimensions...