18
Click to return to the contents section
Installation
Route cable into the opening
• Feed the cable from the amplifier
through the studwork into the
opening to exit above the ALF100SM.
2.5mm
2
(14AWG) stranded cable is
recommended where the cable travels
15m (50 feet) or less, 4mm (12AWG)
for distances over 15m (50 feet).
The image shows cable feeding across
from the side, but a feed down from
the ceiling may be more convenient.
Connecting the ALF100SM
If the fit and cable dressing are correct
then the ALF100SM is ready to be
connected.
• Strip the cables and twist the wire
ends. The cables can be connected
to the terminals unterminated or by
fitting pin crimp terminals. Either
method is acceptable.
• Cables will be marked with a coloured
line or have a moulded rib on one
edge.
By convention this wire is the +
(positive) wire. The unmarked wire is
the - (negative) wire.
coloured line
rib
Strip
Twist
• Connect the cable(s) to the terminal
panel, observing polarity.