MG110P
7.2013
Page 34 of 51
Battery and power levels:
In order to prolong the battery life the controller switches off the display screen of the unit once the keyboard is not
used. In such case the operation of the unit continues as usual. Press any key to switch on the display screen.
The required voltage level for regular operation is 4.7-12 Volts. Once the voltage level drops below 4.7 V the controller
stops its regular operation, switches on the Alarm and enters into Fault status.
I. Technical data
Electrical Connections:
The Electrical Connections Board
External Power supply
6-12 VDC:
This connection terminal is used to connect, when available, a 6-12 VDC 500 milliamp external power supply unit to the
controller.
Once such external power supply is connected the internal batteries of the controller are used only for a backup and not
for the actual operation of the controller.