10
2.2 Lower alarm device instruction
(See Fig.15)
E. Level two platforms and install anchor bolts
1. Check by level bar and use the shim to adjust the platforms until two platforms are in
the same level.
Buffer connecting bar
Limit
Switch
When the machine is lowered to 11-3/4”, the
buffer connecting bar will access to the drive
lever of limit switch, and stop the lift. Pushing
the
button Down
while push the
Lowering
Alarm Button(black)
at the side of control
cabinet, the lift would be lowered down again
with tone of alarm.
Using the Level Bar
for measurement
P
1
P
2
Using the adjusted
shim for the level
Fig. 15
Fig. 16
11
-3
/4