Released 06/2010
E-mail: [email protected]; [email protected]; website: www.amfreece.com
Phone: +420 582 309 286; Fax: +420 582 360 606
DECO 2000
1-56
5 . M A C H I N E D I S P O S A L
1. To ensure ecological disposal it is necessary to remove especially nonmetallic parts from the ma
chine. To take these parts out, it is necessary to perform the partial dismantling of the machine,
remove covers, dismantle the machine arm and remove the frame.
2. Aluminium and duralumin parts must be treated separately, also nonferrous metal parts and plastic
parts
3. Parts mentioned in point 2 can be found in the spare parts manual with these marks:
l
aluminium parts
ll
non - ferrous metal parts
lll
plastic and non - metallic parts
F - MACHINE MAINTENANCE
4. P E R I O D I C M A I N T E N A N C E
once a day
(10 hours of operation)
-cleaning of the sewing mechanism area
-cleaning the inner frame of the machine
-lubrication of the needle bars and sewing mechanisms
once a week
(80 hours of operation)
-visual check - external and internal mechanism
once a month
(300 hours of operation)
-check the screw connections tightening
-check the waste on the control box air grid.
-check the belts tension